I71.4
Conditions
Interventions
Group 1: We aim to compare measurements of cardiac stroke volume with transesophageal echocardiography, transpulmonary thermodilution and pulse contour analysis before and during occlusion in patients
Sponsors
Universitätsmedizin Mannheim, Klinik für Anästhesiologie, Operative Intensiv- und Schmerzmedizin
Eligibility
Sex/Gender
All
Age
18 Years to No maximum
Inclusion criteria
Inclusion criteria: Patients undergoing elective surgical repair of an abdominal aortic aneurysm
Exclusion criteria
Exclusion criteria: • Age < 18 years • Anatomical peculiarities that make it impossible to perform transesophageal echocardiography
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| cardiac stroke volume measured with ransesophageal echocardiography, transpulmonary thermodilution and pulse contour analysis before and during aortic occulsion | — |
Secondary
| Measure | Time frame |
|---|---|
| - lowest intraoperative mean arterial blood pressure during the operation compared to the lowest mean arterial blood pressure determined using ambulatory 24-hour blood pressure measurement before the operation - diastolic function before and during aortic occlusion | — |
Countries
Germany
Contacts
Public ContactJörg Krebs
Universitätsmedizin Mannheim, Klinik für Anästhesiologie, Operative Intensiv- und Schmerztherapie
Outcome results
None listed