H90 Z96.2 Z46.2
Conditions
Interventions
Sponsors
Eligibility
Inclusion criteria
Inclusion criteria: Adult patient with regular unilateral first time CI indication; CI programming allows setting of customized filter bank; Duration of deafness less than 10 years (implanted ear); Complete or near complete insertion of CI-electrode; unilateral provision of CI
Exclusion criteria
Exclusion criteria: Congenital deafness or congenital profound hearing loss, compromised speech development, compromised auditory nerve, CI-programming does not allow setting of individualized filter bank, partial insertion of CI-electrode
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Speech perception measures: Freiburg monosyllable test, free field, 65 dB SPL speech level, average of 2 lists comprising each 20 items. Scores obtained after 3 and 6 months | — |
Secondary
| Measure | Time frame |
|---|---|
| Speech perception scores obtained after 9 months, Speech perception in noise (Oldenburg sentence test, OLSA), speech level 65 dB SPL fixed, adaptive noise level, assessed after 3, 6 and 9 months, subjective individual benefit assessed with questionnaires (SSQ, 19 item HISQUI, questionnaire MuMu), preference rating assessed at 6 and 9 months; and pitch discrimination at 9 months (Subset of Mu.S.I.C test). | — |
Countries
Germany
Contacts
Universitätsklinikum Frankfurt am Main/zentrum der HNO/Audiologische Akustik