Skip to content

Does the use of a feedback system affect nocturnal fatigue during cardiopulmonary resuscitation?

Does the use of a feedback system affect nocturnal fatigue during cardiopulmonary resuscitation?

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
DRKS
Registry ID
DRKS00027309
Enrollment
162
Registered
2022-02-16
Start date
2022-09-28
Completion date
Unknown
Last updated
2026-08-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

I46

Interventions

Group 1: 2x10 minutes of CPR during the day and night by medical staff without feedback device Group 2: 2x10 minutes of CPR during the day and night by medical staff using feedback device

Sponsors

Uniklinik RWTH Aachen - Zentrum für klinische Akut- und Notfallmedizin
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to 65 Years

Inclusion criteria

Inclusion criteria: medically trained personell

Exclusion criteria

Exclusion criteria: pregnancy

Design outcomes

Primary

MeasureTime frame
Comparison of the average pressure depth (mm) of chest compressions with and without feedback at night referring to time intervals at the beginning (30-90s) and at the end (480-540s) of the chest compression performance.

Secondary

MeasureTime frame
We compare the following parameters between the study groups "day without feedback" (dwof) with "night without feedback" (nwof), as well as "day with feedback" (dwf) with "night with feedback" (nwf). The evaluation is based on the total period with chest compressions of 3x2=6 minutes, 1st, 2nd and 3rd cycle of chest compressions (2 minutes each) as well as minute by minute during the cycles with chest compressions. - average pressure depth (mm) of chest compressions - number of chest compressions performed per subject - Number of chest compressions with adequate/too low/too high pressure depth (n), and in relation to the number of chest compressions performed. - Number of chest compressions with correct unloading of the thorax (n), and in relation to the number of chest compressions performed (%) - Number of chest compressions with correct positioning of the hand on the thorax (n), and in relation to the total number of chest compressions performed (%) - Number of effective chest compressions (n) and in relation to the total number of compressions performed (%): composite value of compressions with correct depth of pressure, correct hand position and subsequent correct unloading of the chest - Average compression frequency - "No-flow" time, (defined as an interruption of chest compressions > 2s and if compression depth is <20mm for more than 2 seconds) -Differences in the above parameters depending on gender, age, work experience, body mass index or occupational group (e.g. medical staff, paramedics, nurses).

Countries

Germany

Contacts

Public ContactChristopher Plata

Uniklinik RWTH Aachen - Zentrum für klinische Akut- und Notfallmedizin

cplata@ukaachen.de00492418036013

Outcome results

None listed

Source: DRKS (via WHO ICTRP) · Data processed: Aug 9, 2026