Evaluation of data from the Quantra Hemostasis Analyzer in multiple trauma patients to validate and optimize the existing therapy algorithm.

Evaluation of data from the Quantra Hemostasis Analyzer in multiple trauma patients to validate and optimize the existing therapy algorithm. - GHD (Golden Hour of Diagnostics)

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
DRKS
Registry ID
DRKS00027072
Enrollment
50
Registered
2022-03-07
Start date
2021-03-22
Completion date
Unknown
Last updated
2025-04-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

multiple trauma/ polytrauma trauma-induced coagulopathy D65-D69

Interventions

Group 1: The first blood sample and analysis using the viscoelastic test method (VET) is usually carried out in the trauma room, others will follow as required during the operative care. For this purp

Sponsors

Klinikum Bremen Mitte
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to No maximum

Inclusion criteria

Inclusion criteria: Patients after severe blunt or penetrating trauma with active bleeding or an expected high risk of developing significant bleeding in the course of the disease.

Exclusion criteria

Exclusion criteria: None

Design outcomes

Primary

MeasureTime frame
The aim of the study is to evaluate data from the Quantra Hemostasis Analyzer in multiple trauma patients in order to validate and optimize the existing therapy algorithm. The first blood sample and analysis using the viscoelastic test method (VET) is usually carried out in the trauma room, others will follow as required during the operative care. For this purpose, an additional 3.2 ml of blood is taken from the patient in a standard coagulation tube (citrate tube) approx. 10 minutes after arrival via a venous or arterial puncture with the standard blood samples and analyzed directly in the Quantra Hemostasis Analyzer. The QStat® cassette is used for this. With the QStat® cassette, the extent and the start time of the fibrinolysis can be precisely monitored. In addition, changes in clot strength can be detected with and without the addition of tranexamic acid. With the help of the SEER (Sonic Estimation of Elasticity via Resonance) technology, the blood sample is vibrated by ultrasound and the linear elastic deformation as a result of the applied shear forces is measured. This not only measures the time required for coagulation, but also the mechanical properties of a clot.

Secondary

MeasureTime frame
The collected data should be used to retrospectively determine whether an early statement can be made about the prognosis of the outcome of multiple trauma patients.