Skip to content

The influence of cochlear morphology, insertion angle and - depth, scalar location and position of the first basal electrode following cochlear implantation on speech perception and auditory capacity regarding different electrode arrays; comparing patients following reimplantation, patients with residual hearing and separating patients under and over the age of 70

The influence of cochlear morphology, insertion angle and - depth, scalar location and position of the first basal electrode following cochlear implantation on speech perception and auditory capacity regarding different electrode arrays; comparing patients following reimplantation, patients with residual hearing and separating patients under and over the age of 70 - CMR

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
DRKS
Registry ID
DRKS00019807
Enrollment
1000
Registered
2021-11-25
Start date
2016-11-01
Completion date
Unknown
Last updated
2025-04-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

H90

Interventions

Group 1: patients following CI surgery will be compared regarding scalar position of the electrode array, morphological radiological criteria and postoperative speech perception.

Sponsors

Klinik für Hals- Nasen- Ohrenheilkunde
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to No maximum

Inclusion criteria

Inclusion criteria: Retrospective analysis of CI implanted patients with a device of Cochlear™ (Elektrodentyp: Contour, Contour Advance, Slim straight, slim modular) or MED-EL (SONATA, SYNCHRONY, CONCERTO). Only adults over 18 y.

Exclusion criteria

Exclusion criteria: Implantation of other manufacturers or with other electrode arrays. patients with signs of sclerosis, following meningitis or labyrinthitis, children, malformations or if the CT scans are not sufficient.

Design outcomes

Primary

MeasureTime frame
1. Scalar position depends on cochlear size. 2. scala tympani inserted electrode arrays show better results in postoperative speech perception. 3. position of electrode array dislocation is electrode array design specific.

Secondary

MeasureTime frame
7. patients with deeply inserted electrode arrays do not have adequate stimulation in high frequency range of the basal cochlear turn. 8. patients following reimplantation have worse results in speech perception compared to first implanted patients. 9. there is no significant difference between elderly patients and younger CI recipients. 10. residual hearing detected in a kaplan meier curve depends on electrode array design in length and rigidity.

Countries

Germany

Contacts

Public ContactManuel Christoph Ketterer

Klinik für Hals- Nasen- Ohrenheilkunde

manuel.christoph.ketterer@uniklinik-freiburg.de0049076127041010

Outcome results

None listed

Source: DRKS (via WHO ICTRP) · Data processed: Feb 4, 2026