Skip to content

Investigation of the influence of intraoperative mechanical ventilation on volatile organic compounds in the exhaled air

Investigation of the influence of intraoperative mechanical ventilation on volatile organic compounds in the exhaled air - ClinVILI

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
DRKS
Registry ID
DRKS00017508
Enrollment
40
Registered
2019-06-25
Start date
2019-09-06
Completion date
Unknown
Last updated
2025-04-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ventilator induced lung injury

Interventions

Group 1: Long operative procedures > 4 hours. Analysis of the composition of exhaled air intraoperatively in 5-minute intervals. Group 2: One-lung Ventilation. Analysis of the composition of exhaled a

Sponsors

Universtitätsklinikum des Saarlandes, Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to No maximum

Inclusion criteria

Inclusion criteria: • Patients undergoing elective surgery • Written consent of the patient • Age = 18 years • ASA I-III • No participation in another study (up to 30 days before inclusion in the study) • Total Intravenous Anesthesia (TIVA) with propofol and remifentanil • BMI = 35kg / m² • Inclusion criteria depending on the patient group: o Planned operating time> 4 hours o Planned surgery that requires one-lung ventilation o Planned laparoscopic surgery

Exclusion criteria

Exclusion criteria: • rejection by the patient • pre-existing conditions or patient circumstances that make a patient's examination impossible or meaningless (for example, dementia, psychiatric disorders, lack of speech or speaking skills) • ASA> III • drug abuse • Positive HIV or hepatitis test • Isolation of the patient • pregnancy • contraindications or known incompatibilities with intravenous narcotics used • contraindications for total intravenous anesthesia • Anesthesia guided by volatile anesthetics • BMI> 35kg / m²

Design outcomes

Primary

MeasureTime frame
Influence of mechanical ventilation on the exhaled pentanal concentration

Secondary

MeasureTime frame
Changes in the exhaled volatile organic compounds by mechanical ventilation

Countries

Germany

Contacts

Public ContactLukas Müller-Wirtz

Universitätsklinikum des Saarlandes, Experimentelle Anästhesiologie, Center of Breath Research (CBR)

lukas.wirtz@uks.eu068411622785

Outcome results

None listed

Source: DRKS (via WHO ICTRP) · Data processed: Feb 4, 2026