Lower-limb amputation Q72.0 Q72.9 S78.1 S78.9 T13.6
Conditions
Interventions
Sponsors
Eligibility
Inclusion criteria
Inclusion criteria: Unilateral transfemoral (above the knee) amputations
Exclusion criteria
Exclusion criteria: Participants diagnosed with neurological diseases, cardiovascular or other orthopedic disorders, cancer, pace maker, metall implants, acute inflammation, not yet healed fractures or wounds, feverish diseases, haemophilia, psychogene syndrome, known allergies against electrode gel or pregnancy will be excluded.
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| While participants are standing still on a force measurement platform, data will be obtained about the changes of the center of pressure in their feet and the synchronization of muscle activity. This data will be analysed to be able to compare the complexity of CoP adjustments in participants with lower-limb amputation and the control group. Additionally, amputees will get transcutaneous electrical surface stimulation to take a first step directing to an enahncement of balance control by restoring sensory feedback. | — |
Secondary
| Measure | Time frame |
|---|---|
| General body balance abilities of the participants will be assessed with two standard clinical mobility tests (Berg-Balance-Scale and Timed-Up-and-Go-Test). The results of these tests are in the following correlated with the results from the CoP measurements. | — |
Countries
Germany
Contacts
Laboratory for Biomedical MicrotechnologyDepartment of Microsystems EngineeringUniversity of Freiburg - IMTEK