Skip to content

Effect of acupuncture on retinal microcirculation and function

Effect of acupuncture on retinal microcirculation and function - RVA and acupuncture

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
DRKS
Registry ID
DRKS00013955
Enrollment
30
Registered
2018-03-22
Start date
2017-05-06
Completion date
Unknown
Last updated
2025-04-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

CHRONIC DEGENERATIVE EYE DISEASE H40-H42 H35

Interventions

Group 1: Background of the non-randomized prospective open study is the investigation of the microcirculation with the retinal vessel analyzer, fo objective retinal function with electrophysiological
cervical segmental points at the hand (LI4, Dahlgren Punkt, Punkte nach Boel), Distal points (ST36-LR3. SP6-SP9 & GB37, BL60, BL67) verwendet. Two periorbital points on each side are stimulated at thr

Sponsors

Augenzentrum am Annapark
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to No maximum

Inclusion criteria

Inclusion criteria: Patients with glaucoma and other degenerative retinal or optic nerve disease if acupuncture is being considered.

Exclusion criteria

Exclusion criteria: Patients who for mental, health or legal reasons are unable to understand the course of the study or unable to consent Patients who are unable to focus on the monitor for mfERG or the leading light of the RVA Patients who show eye pathology that would prevent a valid testing with mfERG or RVA Patients who would need to drive the same day (mydriasis) Patients who are pregnant, breastfeeding or cannot exclude a potential pregnancy

Design outcomes

Primary

MeasureTime frame
Spontaneous retinal vascular pulsation, focal structural dynamic changes of the retinal vessels and of vessel stiffness before and after intervention is determined statistically through the reactivity of the vessels. The end point is the variation in vessel diameter in response to flicker stimulation in the video recording expressed in "units of measurement".

Secondary

MeasureTime frame
Visual acuity (in percentage) reading a Snellen's chart, visual field (mean deviation) Humphriss perimeter and Frequency doubling technique, contrast sensitivity (percentage per frequency) reading the CSV-1000 chart, Intraocular pressure (mmHg) with Goldmann tonometer, central retinal potentials (amplitude in mV) with the multifocal pattern electroretinogramme, photopic negative response (quotient) with the flash electroretinogramme, questionnaires regarding psychoemtional state, quality of life (scaled questionnaires). All of those before and after treatment.

Countries

Germany

Contacts

Public ContactEdith Rom

Augenzentrum am Annapark

rom@augenzentrum-annapark.de02404/21001

Outcome results

None listed

Source: DRKS (via WHO ICTRP) · Data processed: Feb 4, 2026