G20 G25.0 G24
Conditions
Interventions
Group 1: Retrospective analysis relating to number of vessels within a diameter of 5 mm within the planned trajectory in ceMRI or in CTA or in both modalities.
Evaluation of distance between vessels,
Sponsors
Universitätsklinikum Freiburg, Sterotaktische und Funktionelle Neurochirurgie
Eligibility
Sex/Gender
All
Age
1 Years to 100 Years
Inclusion criteria
Inclusion criteria: Patients with DBS operation for which a preoperative ceMRI, CTA and a postoperative native CT were available. Treatment of patients between 04/2014 and 01/2017.
Exclusion criteria
Exclusion criteria: Patients with DBS operation for which a preoperative ceMRI, CTA and a postoperative native CT were not available.
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Number of depicted vessels within a 5 mm diameter around the planned trjectory in ceMRI and CTA and in the combination of both ceMRi and CTA | — |
Secondary
| Measure | Time frame |
|---|---|
| Distance measured if vessel was visible in both modalities. Total number of intracranial bleedings. | — |
Countries
Germany
Contacts
Public ContactMarie Krüger
Universitätsklinikum Freiburg, Stereotaktische und Funktionelle Neurochirurgie
Outcome results