I35.0 I42.8
Conditions
Interventions
Sponsors
Eligibility
Inclusion criteria
Inclusion criteria: Inclusion criteria study group aortic stenosis and left ventricular failure - Severe aortic stenosis ( valve area 1 years - Consent to participate in the study Inclusion criteria control group aortic stenosis without left ventricular failure - Severe aortic stenosis ( valve area 1 years - Consent to participate in the study
Exclusion criteria
Exclusion criteria: - Active endocarditis - Previous heart surgery - Concurrent serious stenosis or insufficiency of the mitral valve - Concurrent serious insufficiency of the aortic valve - Pregnancy, lactation
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Comparison of reversible and irreversible left ventricular failure in terms of the end-systolic pressure-volume relationship (ESPVR) - measured with conductance catheter - before aortic valve replacement | — |
Secondary
| Measure | Time frame |
|---|---|
| Comparison of reversible and irreversible left ventricular failure: - All-cause mortality (one-year) - Cardiovascular mortality (one-year) - Hospitalization for heart failure (within the first year after aortic valve replacement) - Distance in the 6-minute walk test before and 3 months after aortic valve replacement | — |
Countries
Germany
Contacts
Kardiogische Klinik, Marien-Hospital Witten, Ruhr-Universität Bochum