Skip to content

Development und validation of a new approach for perioperative, non continuous, non-invasive measurement of blood pressure, pulse pressure variation and stroke volume in mechanically ventilated patients in patients undergoing cardiac surgery

Development und validation of a new approach for perioperative, non continuous, non-invasive measurement of blood pressure, pulse pressure variation and stroke volume in mechanically ventilated patients in patients undergoing cardiac surgery - NISMO

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
DRKS
Registry ID
DRKS00009546
Enrollment
60
Registered
2015-11-09
Start date
2015-04-20
Completion date
Unknown
Last updated
2025-04-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

blood pressure, stroke volume, stroke volume variation, pulse pressure Variation of patients unerrgoing cardiac surgery

Interventions

Group 1: Recording and comparing arterial blood pressure and hemodynamic paramters with established and new peizo-foil based monitoring devices in patients undergoing cardiac surgery

Sponsors

Klinik für Anästhesiologie mit Schwerpunkt operative Intensivmedizin, Campus Charite Mitte und Virchow Klinikum, Charite - Universitätsmedizin Berlin
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to No maximum

Inclusion criteria

Inclusion criteria: Informed consent from patient, age = 18 years, cardiac surgery, no paritcipation in a drug trial, surgery under general anesthesia

Exclusion criteria

Exclusion criteria: No informed consent, patients unable to consent, pergnant or breast feeding women, emergency surgery, side difference of blood pressure > 12 mmHg, tissue ischemia, Severe peripheral arterial vascular occlusion disease = 4 after Fontaine, atrial fibrillation, need of intra aortic balloon pump

Design outcomes

Primary

MeasureTime frame
Measurement of blood pressure (absolute and trending) by use of piezo-foil technology and invasively in the perioperative setting.

Secondary

MeasureTime frame
Measurement of pulse pressure and stroke volume variation by use of piezo-foil technology and invasively in the perioperative setting.

Countries

Germany

Contacts

Public ContactViktor Mezger

Klinik für Anästhesiologie mit Schwerpunkt operative Intensivmedizin, Campus Charite Mitte und Virchow Klinikum, Charite - Universitätsmedizin Berlin

viktor.mezger@charite.de030450631177

Outcome results

None listed