Skip to content

Study on the Application Value of Automated Algorithmic Analysis of Pathological High-Frequency Oscillations in Epileptogenic Zone Localization

Study on the Application Value of Automated Algorithmic Analysis of Pathological High-Frequency Oscillations in Epileptogenic Zone Localization

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ChiCTR
Registry ID
ChiCTR2500114937
Enrollment
Unknown
Registered
2025-12-19
Start date
2025-12-20
Completion date
Unknown
Last updated
2026-01-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Epilepsy

Interventions

Gold Standard:Stereotactic Intracranial Electrode Implantation
Index test:Computer-Automated Epileptic Seizure Analysis

Sponsors

Henan Provincial People's Hospital
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: 1. Patients with drug-resistant epilepsy; 2. Patients who, after evaluation by scalp video EEG, neuroimaging, neuropsychological assessment, etc., undergo surgical procedures, stereotactic deep electrode implantation, or subdural electrode implantation; 3. Patients without severe intellectual disabilities, able to cooperate and complete experimental tasks; those with a MoCA score below 26 are not to participate in the study; 4. The subject or the subject's guardian agrees to participate and signs the consent form.

Exclusion criteria

Exclusion criteria: 1. There are severe visual or hearing impairments, and due to other organic issues, the person cannot normally understand language; the examiner will ask the patient or their family whether they are willing to participate in this project. A comprehensive assessment will be conducted based on the difficulty of the cognitive experimental tasks and the patient's cognitive ability, developmental status, motor function, emotional state, etc. If the MoCA score is less than 26, the individual will not participate in the study; 2. The control group has severe underlying diseases or other serious neurological disorders besides epilepsy.

Design outcomes

Primary

MeasureTime frame
Spatial consistency between pathological high-frequency oscillation regions detected by various algorithms and clinical assessments;

Secondary

MeasureTime frame
Evaluation of the resection rate of pathologic high-frequency oscillations detected by various algorithms and the Engel classification of seizure control one year after surgery;Behavioral assessment score of auditory comprehension ability;Speech Communication Ability Behavior Assessment Score;Language Literacy Behavior Assessment Score;