Skip to content

Application of a Single-Use Adjustable Video Laryngeal Mask Airway in Elderly Patients Undergoing Laparoscopic Cholecystectomy

Application of a Single-Use Adjustable Video Laryngeal Mask Airway in Elderly Patients Undergoing Laparoscopic Cholecystectomy

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ChiCTR
Registry ID
ChiCTR2500101513
Enrollment
Unknown
Registered
2025-04-25
Start date
2026-03-02
Completion date
Unknown
Last updated
2026-03-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None

Interventions

The Disposable Conventional Laryngeal Mask Airway Group(Slipa Laryngeal Mask)(Control Group,Group B):Use a disposable conventional laryngeal mask airway for ventilation
The Disposable Adjustable Visual Laryngeal Mask Airway Group(Experimental Group,Group A):Use a disposable adjustable visual laryngeal mask airway for ventilation

Sponsors

West China Hospital of Sichuan University
Lead Sponsor

Eligibility

Sex/Gender
All
Age
65 Years to No maximum

Inclusion criteria

Inclusion criteria: 1.Aged 65 years or older. 2.American Society of Anesthesiologists (ASA) physical status classification of I to III; 3.Patients scheduled for laparoscopic cholecystectomy; 4.Signed informed consent;

Exclusion criteria

Exclusion criteria: 1.Patient or family refusal; 2.Participation in another clinical study prior to enrollment; 3.Limited mouth opening(less than two transverse finger widths); 4.Presence of oropharyngeal deformities or other pathological changes; 5.Patients with a documented history of difficult airway management(including difficult mask ventilation and difficult intubation); 6.High risk of vomiting,aspiration,or a history of recurrent vomiting episodes; 7.Severe obesity(BMI>30 kg/m²);

Design outcomes

Primary

MeasureTime frame
First-attempt success rate of laryngeal mask airway insertion;The incidence of postoperative hoarseness;The incidence of postoperative sore throat;The incidence of blood-stained laryngeal mask airway after surgery.;

Secondary

MeasureTime frame
The number of cases in which the laryngeal mask airway was replaced with a tracheal tube from the time of anesthesia induction to the end of surgery.;The time required for laryngeal mask airway insertion;The overall success rate of laryngeal mask airway insertion;Airway seal pressure after the placement of the laryngeal mask airway.;The quality of screen imaging of the disposable adjustable visual laryngeal mask airway;The number of attempts for laryngeal mask airway insertion;Airway pressure after successful placement of the laryngeal mask airway;The ease of laryngeal mask airway insertion;The glottic exposure grade and the highest alignment accuracy of the disposable adjustable visual laryngeal mask airway and the disposable laryngeal mask airway under fiberoptic bronchoscopy.;The number of adjustments for laryngeal mask airway displacement during surgery.;The probability of air leakage with the laryngeal mask airway.;Airway pressure during mask ventilation (VCV 6 ml/kg, RR 12 breaths/min).;

Countries

China

Contacts

Public ContactJun Ma

West China Hospital of Sichuan University

371065160@qq.com+86 15281062367

Outcome results

None listed

Source: ChiCTR (via WHO ICTRP) · Data processed: Apr 3, 2026