Skip to content

Application study of wireless pressure sensor in unicompartmental knee arthroplasty

Application study of wireless pressure sensor in unicompartmental knee arthroplasty

Status
Recruiting
Phases
Early Phase 1
Study type
Interventional
Source
ChiCTR
Registry ID
ChiCTR2500096468
Enrollment
Unknown
Registered
2025-01-24
Start date
2024-07-18
Completion date
Unknown
Last updated
2025-01-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

knee osteoarthritis

Interventions

experimental group:The measurement method of tension sensor was used during the operation, that is, the tension sensor cue data was used to evaluate the balance of flexion and extension. If the patien
control group:The traditional surgical measurement method was used, that is, the intraoperative gap measuring instrument was used to evaluate the flexion and extension balance. In unicondylar joint re

Sponsors

Xuanwu Hospital, Capital Medical University
Lead Sponsor

Eligibility

Sex/Gender
All
Age
50 Years to 85 Years

Inclusion criteria

Inclusion criteria: (1) Repeated pain in the joint knee for nearly one month; (2) The X- ray (flat or load position) indicates the narrowing of the joint, the hardening of the bone and the cystic change of the cartilage, and the formation of the joint. (3) Age limit: age >= 50 years and age <= 85 years , either sex; (4) The weight index (BMI) limit: 18<= BMI<= 35. (5) Fit with the uka surgical indications; (6) Agree to accept the use of the UKA surgery (by a senior professional professional officer, with a unified, standardized UKA technology, and the use of the same manufacturer); (7) Promise to be able to cooperate with specific treatment: the time review and the unified formal rehabilitation exercise.

Exclusion criteria

Exclusion criteria: (1) Primary osteoarthritis with lateral intercompartment involvement of the knee or severe degeneration of the patellofemoral joint; (2) Flexion contracture >= 15 degrees; (3) Varus deformity >= 15 degrees or MPTA = 5mm; (5) Chronic diseases affecting normal walking, such as cardiovascular and cerebrovascular diseases, cervical and lumbar vertebrae diseases and lower extremity arteriovenous diseases; (6) Rheumatoid arthritis, bone tumor or Paget disease

Design outcomes

Primary

MeasureTime frame
Oxford Knee Score (OKS);

Secondary

MeasureTime frame
Oxford Knee Score (OKS);Tension sensors measure the tension value of the medial space of the knee joint;The accuracy of prosthesis placement based on CT measurement reached the standard rate;Compliance rate of lower limb force line based on X-ray measurement;NRS;SF-12;

Countries

China

Contacts

Public ContactShuai An

Xuanwu Hospital, Capital Medical University

anshuai1022@hotmail.com+86 134 0116 1758

Outcome results

None listed

Source: ChiCTR (via WHO ICTRP) · Data processed: Feb 4, 2026