Skip to content

Clinical study of non-contact atrial fibrillation detection methods based on optical fiber sensors

Clinical study of non -contact atrial fibrillation detection methods based on optical fiber sensors

Status
Active, not recruiting
Phases
Early Phase 1
Study type
Observational
Source
ChiCTR
Registry ID
ChiCTR2500095454
Enrollment
Unknown
Registered
2025-01-07
Start date
2025-02-10
Completion date
Unknown
Last updated
2025-01-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial fibrillation

Interventions

Gold Standard:ECG detection, the device is used as a Japanese optoelectronics electrocardium 2550 (NIHON KOHDEN ECG2550). ECG doctor judged the diagnosis of the ECG diagnosis based on ECG. Features o
(3) The most obvious leader in the principle of F wave in V1 is the second, followed by leader ?, ?, and AVF. (4) The ventricular rate is absolutely uneven
(5) The shape of the QRS wave cluster is generally normal, and indoor differences or the original bouquet tributary blocking occurs, and the QRS wave group is wide.
Index test:Non-contact atrial fibrillation detection methods based on optical fiber sensors

Sponsors

The First Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine
Lead Sponsor

Eligibility

Sex/Gender
All
Age
60 Years to No maximum

Inclusion criteria

Inclusion criteria: 1) Age: over 60 years old; 2) ECG meets the diagnostic standards of atrial fibrillation; 3) Be able to communicate well with researchers and follow the entire test requirements; 4) Patients voluntarily participate in this study and signed a written informed consent, and are willing to cooperate with follow -up.

Exclusion criteria

Exclusion criteria: 1) Patients who cannot monitor ECG; 2) History of diseases that may affect the compliance of the scheme (such as severe mental disorders, cognitive dysfunction, drug abuse or addiction, etc.); 3) In any case, if the researchers believe that the subject is not suitable for this test (such as the subject is unwilling to avoid other tests, the subject is unwilling to accept the research plan, the expected value of the subject There are obvious emotional problems). 4) Patients with atrial fibrillation height, ? degree room conduction block, atrial fibrillation combined with pacemaker implantation.

Design outcomes

Primary

MeasureTime frame
ECG;The area under the AUC curve, AUC;Sensitivity;Specificity;

Countries

China

Contacts

Public ContactHui Wu

The First Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine

wuhui026@163.com+86 138 2605 8026

Outcome results

None listed

Source: ChiCTR (via WHO ICTRP) · Data processed: Feb 4, 2026