Skip to content

Research on Thyroid CT Examination Protocol Using Assistive Body Positioning Device and Artificial Intelligence Automatic Localization Technology

Research on Thyroid CT Examination Protocol Using Assistive Body Positioning Device and Artificial Intelligence Automatic Localization Technology

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ChiCTR
Registry ID
ChiCTR2400079494
Enrollment
Unknown
Registered
2024-01-04
Start date
2024-05-06
Completion date
Unknown
Last updated
2024-12-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

thyroid disease

Interventions

Manual Positioning Experimental Group A:Manual positioning involves changing the position of the thyroid at the shoulder, with the assistance of additional positioning techniques, to reduce artifacts
Manual Positioning Control Group B:Manual positioning involves routine positioning for thyroid examination without any intervention.
Assisted Positioning Experimental Group A:AI positioning involves changing the position of the thyroid at the shoulder, with the assistance of additional positioning techniques, to reduce artifacts ca
Assisted Positioning Control Group B:Manual positioning involves changing the position of the thyroid at the shoulder, with the assistance of additional positioning techniques, to reduce artifacts cau

Sponsors

Zhangzhou Affliliated Hospital of Fujian Medical University
Lead Sponsor

Eligibility

Sex/Gender
All
Age
16 Years to 80 Years

Inclusion criteria

Inclusion criteria: Inclusion Criteria: 1.No restrictions on gender or age; 2.Patients and their families are informed about this study and have signed an informed consent form; 3.Age 16 years and older, able to cooperate with the instructions of technical staff; 4.Patients who have not been injected with iodine contrast agent in the last 14 days.

Exclusion criteria

Exclusion criteria: Exclusion Criteria: 1.Patients currently undergoing treatment for hyperthyroidism; 2.Patients who cannot discontinue metformin; 3.Patients with severe liver or kidney dysfunction; 4.Pregnant women.

Design outcomes

Primary

MeasureTime frame
Thyroid artifact percentage;Artifact index;Contrast-to-Noise Ratio (CNR) of the maximum region with artifacts;Signal-to-Noise Ratio (SNR) of the maximum region with artifacts;Contrast-to-Noise Ratio (CNR) of the minimum region with artifacts;Signal-to-Noise Ratio (SNR) of the minimum region with artifacts;Estimated radiation dose for the thyroid;Radiation doses on dose reports for plain, arterial, and venous phases;Size-Specific Dose Estimate with effective diameter (SSDEed);DLPssde;Maximum diameter of the thyroid in the neck anterior-posterior direction;Actual centerline distance on the axial image of the maximum cross-section of the thyroid;Distance from the actual centerline to the positioning centerline;

Secondary

MeasureTime frame
Contrast Agent Total Amount;Contrast Agent Flow Rate;

Countries

China

Contacts

Public ContactWeihua Lin

Zhangzhou Affliliated Hospital of Fujian Medical University

Linweihua128@163.com+86 138 5051 5128