pelvic fractures
Conditions
Interventions
modified percutaneous patient specific three- dimensional printed guide template group:The iliosacral screw was inserted for fixation of the posterior pelvic ring fracture with the assitance of modifi
the conventional fluoroscopy group:the iliosacral screw was inserted under the guidance of conventional fluoroscopy. The operation time, fluoroscopy frequency, intraoperative blood loss and incision l
Sponsors
the 3rd Hospital of Changsha
Eligibility
Sex/Gender
All
Age
18 Years to 70 Years
Inclusion criteria
Inclusion criteria: Patients aged between 18 and 70 years old who sustained unstable pelvic fractures.
Exclusion criteria
Exclusion criteria: Patients complicated with nerve injuries, malignant tumors, pregnancy, immune system diseases, and patients taking immunosuppressant.
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| operation time for each screw insertion;fluoroscopy frequency;fracture reduction assessment ;screw position assessment;functional outcome; | — |
Secondary
| Measure | Time frame |
|---|---|
| intraoperative blood loss ;incision length; | — |
Countries
China
Contacts
Public ContactLIU FENG
the 3rd Hospital of Changsha
Outcome results