Withdraw due to duplicate registration. Application of Do-It-Yourself Hybrid Closed-loop Artificial Pancreas System in Chinese Adults with Type 1 Diabetes Mellitus

Application of Do-It-Yourself Hybrid Closed-loop Artificial Pancreas System in Chinese Adults with Type 1 Diabetes Mellitus

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ChiCTR
Registry ID
ChiCTR2300068432
Enrollment
Unknown
Registered
2023-02-19
Start date
2023-02-11
Completion date
Unknown
Last updated
2023-05-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

type 1 diabetes mellitus

Interventions

A:The DIY hybrid closed-loop artificial pancreas system was used during the first 12-week treatment period, and sensor augmented insulin pump therapy was used during the second 12-week treatment perio
B:Sensor augmented insulin pump therapy was used during the first 12-week treatment period and the DIY hybrid closed-loop artificial pancreas system was used during the second 12-week treatment period

Sponsors

The Third Affiliated Hospital of Sun Yat-sen University
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to 75 Years

Inclusion criteria

Inclusion criteria: 1) Patients with type 1 diabetes mellitus (T1DM) diagnosed by endocrinologists, with diabetes duration >=1 year; 2) Aged 18-75 years old; 3) Glycated hemoglobin level between 7.0% and 11%; 4) Use of multiple daily injections or insulin pump therapy for >=3 months; 5) Total daily insulin dose >=0.3 unit/kg body weight/day and basal rate >=0.05 unit/hour; 6) Regular self-monitoring of blood glucose (SMBG) (>=3 times a day) for >=2 months; 7) Live with an adult willing to care for the subject during the study period; 8) Willingness of women of childbearing age to use appropriate contraceptive methods; 9) Signed informed consent.

Exclusion criteria

Exclusion criteria: Persons with any of the following were excluded from the trial 1) With severe acute or chronic diabetic complications; 2) Frequent severe hypoglycemia in the past 3 months; 3) Patients who used closed-loop in the past 2 months (no need to exclude those who used continuous glucose monitoring recently); 4) Impaired liver function (alanine aminotransferase [ALT] > 2.5 times the upper limit of normal); 5) Moderate to severe renal impairment defined as estimated glomerular filtration rate (eGFR) < 60ml/min/1.73m^2 calculated by MDRD equation; 6) Clinically significant cardiac disease; 7) Pregnancy and lactation; 8) Use of medications known to interfere with glucose metabolism within the past 8 weeks; 9) Regular use of acetaminophen; 10) Known to be allergic to medical-grade adhesives; 11) Other physical or psychological conditions deemed by the investigator to be inappropriate for enrollment.

Design outcomes

Primary

MeasureTime frame
glycosylated hemoglobin;Fingertip blood glucose values;Continuous blood glucose monitoring indicators;

Secondary

MeasureTime frame
Diabetes distress scale (Chinese version);EQ-5D-5L scale;hemoglobin;Diabetes Distress Scale;Red Blood Cell Count;lipidprofile;blood uric acid;Serum creatinine;Urinary protein/creatinine ratio;alanine aminotransferase;aspartate aminotransferase;serum insulin;Serum C-peptide;

Countries

China

Contacts

Public ContactWen Xu

The Third Affiliated Hospital of Sun Yat-sen University

xwen@mail.sysu.edu.cn+86 186 6572 7475

Outcome results

None listed