Clinical study of cervical lymphatic ultrasound image analysis software

Clinical study of cervical lymphatic ultrasound image analysis software

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ChiCTR
Registry ID
ChiCTR2300067940
Enrollment
Unknown
Registered
2023-02-01
Start date
2023-02-01
Completion date
Unknown
Last updated
2023-05-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cervical lymph

Interventions

Sponsors

Shanghai Sixth People's Hospital
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: 1. The cases corresponding to the included cervical lymphatic images must be patients who underwent cervical lymphatic ultrasound imaging in Shanghai Sixth People's Hospital and Shanghai Dongfang Hospital after January 2017, and the ultrasound images of the largest section of cervical lymph at the time of examination were taken; 2. The cervical lymphatic ultrasound image is clear and complete, meets the requirements of ultrasound quality control, the resolution is not less than 480P, and it meets the common conditions of clinical diagnosis; 3. For patients without gender and age ratio requirements, ultrasound images of imaging examination are randomly selected; 4. Ultrasound images contain at least 1 lymph and no more than 3 lymphs; 5. Contain as much as possible normal lymph, abnormal lymph in different states of common conditions; 6. Two-dimensional ultrasound images of cervical lymph acquired by more than two brands of ultrasound equipment need to be included;

Exclusion criteria

Exclusion criteria: 1. Cervical lymphatic ultrasound images of patients admitted to the hospital with a history of lymphoma or surgery; 2. In multiple lymphs, or lymphatic overlapping ultrasound images, none of the lymph is completely displayed; each lymph is occluded, unclear, or out of range of the image. In these cases, this ultrasound image should be excluded from the study data; 3. Ultrasound images that are not suitable for clinical research in the judgment of the investigator include but are not limited to the following: the lymphatic region of the ultrasound image is marked, which affects the observation and analysis; Investigator considers it inappropriate to participate in clinical studies due to patient considerations; with other pathologies, conditions that interfere with lymphatic analysis; 4. Ultrasound images with incomplete case information and untraceable origin; 5. Cervical lymphatic ultrasound images that cause the leakage of personal privacy information of the patient due to human or equipment reasons.

Design outcomes

Primary

MeasureTime frame
Consistency of a single feature of cervical lymph nodes;

Secondary

MeasureTime frame
Kappa coefficient;Software and gold standards are accurate in determining all features (aspect ratio, morphology, boundaries, echo, calcification, lymphgate) of the same 2D ultrasound image of cervical lymph;