Validation for Pulse Saturation Accuracy of Pulse Oximeters

Validation for Pulse Saturation Accuracy of Pulse Oximeters

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ChiCTR
Registry ID
ChiCTR2200056399
Enrollment
Unknown
Registered
2022-02-05
Start date
2022-02-10
Completion date
Unknown
Last updated
2024-09-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Interventions

Gold Standard:SaO2 measurement value of ABL90FLEX (CO oximeter) instrument blood gas analyzer
Index test:Pulse Saturation Accuracy of Pulse Oximeters

Sponsors

SHENZHEN UNIVERSITY GENERAL HOSPITAL
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to 50 Years

Inclusion criteria

Inclusion criteria: 1. Healthy adults aged between 18 and 50 years (male and female, including dark, medium and light skin, should have at least 2 person or 15% people are dark-skinned); 2. Normal or abnormal vital signs, physical examination, 12-lead electrocardiogram, chest X-ray, laboratory examination (including blood routine, urine routine, coagulation function, blood biochemistry and other functions) have no clinical significance; 3. Agree to participate in the study voluntarily and sign the Informed Consent Form; 4. Artery Blood Gas analysis under breathing air: SaO2 > 95%; COHb10g/ dL.

Exclusion criteria

Exclusion criteria: 1.Those who smoked more than 10 cigarettes per day within 3 months before filtering and those could not accept smoking ban after filtering during the test period, or those were exposed to high carbon monoxide environment; 2.Patients with a history of heart and lung diseases; 3.Blood pressure and heart rate cannot be controlled within the normal range (systolic blood pressure >= 140 mmHg and/or diastolic blood pressure >= 90 mmHg; Or hypotension: blood pressure below 90/60mmHg; Heart rate 100 BPM); 4.Platelet count < 60 x 10^9/L or patients with blood coagulation disorders; 5.Those who have donated blood in the past six months; 6.Those who have participated in degree verification of pulse blood oxygen saturation (invasive) within one month or clinical trials of other drugs or medical devices within three months; 7.Pregnant or lactating women (pregnancy in this study is defined as positive urine pregnancy test) or those who have a birth plan within the next month (<=30 days); 8.Those that the investigator considers not suitable for this clinical trial for other reasons.

Design outcomes

Primary

MeasureTime frame
Pulse Saturation Accuracy of Pulse Oximeters;Accuracy ;

Countries

CHINA

Contacts

Public ContactHan Wei

SHENZHEN UNIVERSITY GENERAL HOSPITAL

18813980300@139.com+86 18813980300