Skip to content

Studying how different head and neck positions affect the fit of a breathing mask used during surgery

Influence of different head and neck positions on oropharyngeal leak pressure with laryngeal mask airway protector in elective surgeries - NIL

Status
Active, not recruiting
Phases
Phase 4
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2025/08/093050
Enrollment
60
Registered
2025-08-14
Start date
Unknown
Completion date
Unknown
Last updated
2025-08-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: O- Medical and Surgical

Interventions

Intervention1: Supraglottic airway device: Supraglottic airway device(LMA PROTECTOR) will be inserted after induction and neuromuscular blockade to secure the airway.The Oropharyngeal Leak Pressure in

Sponsors

Government Medical College and Hospital
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: 1.Patients with American society of anaesthesiologist physical status grade 1 and 2 2.age between 18-70 3.patients undergoing elective surgeries requiring controlled ventilation under general anaesthesia.

Exclusion criteria

Exclusion criteria: 1. Patients with anticipated difficult airway Airway Difficulty Score 2. Morbid obesity 3. Pregnant women 4. Major maxilla-facial trauma or cervical spine pathology 5. Severe cardiorespiratory, cerebrovascular, renal, hepatic or musculoskeletal diseases 6. Severe coagulopathy or history of anticoagulant use 7. Patients at increased risk of pulmonary aspiration such as gastroesophageal reflux disease, peptic ulcer disease, full stomach 8. Surgery in prone position

Design outcomes

Primary

MeasureTime frame
Comparing the difference in oropharyngeal leak pressure with changes in head and neck positions using the LMA Protector airway deviceTimepoint: After induction and 5minutes after neutral head position,5minutes after flexion head position,5minutes after extension head position,5minutes after right lateral position and 5minutes after left lateral head position.

Secondary

MeasureTime frame
1.To study the insertion time of LMA Protector 2.To study the number of attempt required for insertion 3.To study the ease of insertion of the device 4.To study hemodynamic variations in different head & neck positions 5.To study fiberoptic assessment of glottic view through the device. 6.To study post-operative complications such as sore throat, stridor or hoarseness, dental trauma, any other relevant complications.Timepoint: 1.After insertion of LMA device 2.After insertion of LMA device 3.After indertion of LMA device 4.5minutes after each head position flexion,extension,neutral,right lateral,left lateral head position 5.30 minutes after insertion of LMA device 6.Immediately after removal of LMA tube to 48 hours after removal to tube

Countries

India

Contacts

Public ContactDr Vanita Ahuja

Government Medical College and Hospital,Chandigarh

dpkthapa@gmail.com9646121524

Outcome results

None listed

Source: CTRI (via WHO ICTRP) · Data processed: Feb 4, 2026