Skip to content

A comparative study of three supraglottic airway devices laryngeal mask airway, laryngeal mask protector and baska in terms of their airway sealing pressures in neutral and lateral positions in patients under general anaesthesia.

Comparison of oropharyngeal leak pressure of laryngeal mask airway protector laryngeal mask airway proseal and baska in anaesthetised and paralysed patients in neutral and lateral positions a randomised double blinded control study - NIL

Status
Active, not recruiting
Phases
Phase 4
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2025/07/090357
Enrollment
75
Registered
2025-07-07
Start date
Unknown
Completion date
Unknown
Last updated
2025-07-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: 4- Measurement and Monitoring

Interventions

Intervention1: Insertion of laryngeal mask airway protector and baska: To compare the insertion characteristics and oropharyngeal leak pressure in neutral and lateral positions in anaesthetised and p

Sponsors

Chettinad hospital and research institute
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: Patient aged 18 to 70 years belonging to ASA 1physical status I and II undergoing elective surgery for 1 to 3 hours under general anaesthesia will be included.

Exclusion criteria

Exclusion criteria: Patients with known difficult airway, edentulous, body mass index more than 30, upper airway pathology, mouth opening less than 3.2 cm, gastroesophageal reflux, increased risk of aspiration, recent upper respiratory tract infection, and lack of consent to participate will be excluded from the study.

Design outcomes

Primary

MeasureTime frame
COMPARISON OF OROPHARYNGEAL LEAK PRESSURE OF LARYNGEAL MASK AIRWAY PROTECTOR , LARYNGEAL MASK AIRWAY PROSEAL AND BASKA IN NEUTRAL AND LATERAL POSITIONSTimepoint: 0 minutes 3 minutes 6 minutes and 9 minutes after insertion

Secondary

MeasureTime frame
To compare the insertion characteristics of LMA protector ,LMA proseal and BASKA in terms of : Time taken for successful insertion Ease of insertion Number of attempts required for insertion Ease of NG tube placement Grading of fibre optic view of laryngeal structures Blood stain present on removal of device To look for any postoperative side effects like sore throat, dysphagia, hoarseness of voice. Timepoint: Hemodynamic monitoring BP, HR, Spo2 at 0min, 3mins, 6min and 9 min after supraglottic airway device insertion.

Countries

India

Contacts

Public ContactDr Arun Kumar

Chettinad hospital and research institute

pugalenthi08@yahoo.co.in9489404818

Outcome results

None listed