Skip to content

Comparision of supraglottic airway devices in laparoscopic cholecystectomy patients

Comparision of efficacy of Air Q laryngeal mask airway and Baska mask in patients undergoing laparoscopic cholecystectomy: A prospective randomized clinical study - nil

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2024/10/074678
Enrollment
80
Registered
2024-10-03
Start date
Unknown
Completion date
Unknown
Last updated
2024-10-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: 4- Measurement and Monitoring Health Condition 2: O- Medical and Surgical

Interventions

Control Intervention1: Air Q LMA: The air-Q ® Intubating Laryngeal Airway (air-Q
Mercury Medical, Clearwater, FL, USA) is a new supraglottic airway device (SAD) intended for use as a primary airway as well as an aid for tracheal intubation in situations of anticipated or unanticip

Sponsors

JLN medical college
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: Age 18 to 60years. ASA grade I & II. BMI less then 30. Under going laparoscopic cholecystectomy under general anaesthesia. Surgery lasting up to 90 minutes.

Exclusion criteria

Exclusion criteria: ASA grade III and above. Known difficult airway (with recent history upper respiratory tract infection, any obvious scar or mass or ulcer in neck, cleft lip/palate, adenotonsilar hypertrophy or lingual tonsils , obese syndromic, microganthia, congenital malformations involving respiratory tract, cervical spine disorder). Mouth opening less then 2.5 cm . With increase risk of aspiration of gastric contents (NBM status unknown, non fasted, gastrointestinal stricter or stenosis ). Obesity BMI more then 30kg per meter square. Negative patient consent. Pregnant patient

Design outcomes

Primary

MeasureTime frame
Oropharyngeal leak pressure of air Q LMA and Baska maskTimepoint: Grading point system

Secondary

MeasureTime frame
1 Number of attempts for successful insertion of Air Q LMA and Buska mask 2 Time taken for successful insertion of the devices 3 Ease of successful insertion of orogastric tube through the drain tube of both the devices 4 Flexible fiberoptic visualization of glottic through the airway tube of both the devices 5 Hemodynamic variables heart rate, systolic BP, diastolic BP, mean arterial pressure 6 Peak airway pressure pre and post pneumoperitonium following insetion of both the devices. 7 Incidence of postoperative adverse events between Air Q LMA and Baska mask like- Blood staining on device Sore throat Hoarseness of voice Aspiration RegurgitationTimepoint: Subjective scale and grading point system

Countries

India

Contacts

Public ContactDr Arvind Khare

Jawahar lal Nehru medical college , Ajmer , Rajasthan

arvindkhare68@gmail.com9414306114

Outcome results

None listed

Source: CTRI (via WHO ICTRP) · Data processed: Feb 4, 2026