Skip to content

Comparison of two different airways in Patients undergoing General Anaesthesia

Comparison of Laryngeal Mask Airway Protector versus Laryngeal Mask Airway Blockbuster in Patients undergoing General Anaesthesia: A Randomised Control Study - NIL

Status
Active, not recruiting
Phases
Phase 4
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2024/09/073673
Enrollment
66
Registered
2024-09-09
Start date
Unknown
Completion date
Unknown
Last updated
2024-09-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: O- Medical and Surgical

Interventions

Intervention1: LMA PROTECTOR: After the device ( LMA PROTECTOR) is properly inserted,presence of an effective airway is verified. Correct Positioning will be confirmed.The oropharyngeal seal pressure

Sponsors

Rohilkhand Medical College and Hospital
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: 1.Patients undergoing elective surgeries under general anesthesia 2. Age between 18 to 60 years 3. ASA physical status of I or II 4.Mallampati Classification (MMT) of I & II 5. BMI = 30 kg/m²

Exclusion criteria

Exclusion criteria: 1. Morbid Obesity, Pregnancy. 2. Patient with neck pathology 3. Anticipated difficult airway 4. Pre-existing cervical spine disease 5. History of gastro-oesophageal reflux or increased risk of Gastric aspiration. 6. Lesion in oral cavity 7. Loose denture 8. Head & Neck surgeries

Design outcomes

Primary

MeasureTime frame
1.Time taken for insertion of Supraglottic Airway Devices. 2.Total number of attempts 3.Ease of Insertion 4.Oropharyngeal seal pressure 5.Blood stain on the device 6.Sore throat 7.Airway trauma Timepoint: Before LMA insertion, At the time of LMA Insertion, every 5 minutes after LMA insertion till 60 minutes , then every 10 minutes and immediately after the removal of the device.

Secondary

MeasureTime frame
Hemodynamic parameters like Systolic Blood Pressure(SBP), Diastolic Blood Pressure(DBP), Mean Arterial Pressure(MAP), Heart Rate(HR), SpO2Timepoint: Before LMA insertion, At the time of LMA Insertion, every 5 minutes after LMA insertion till 60 minutes , then every 10 minutes and immediately after the removal of the device.

Countries

India

Contacts

Public ContactDr Prajwalit Bhanu

Rohilkhand Medical College and Hospital

ankurgarg.gsvm@gmail.com9650715363

Outcome results

None listed

Source: CTRI (via WHO ICTRP) · Data processed: Feb 4, 2026