Skip to content

Checking the fit of upper complete denture bases using different methods

Retention of maxillary complete denture bases achieved through posterior palatal seal registrations with conventional and functional swallow methods using two different border moulding materials - An In-vivo study - NIL

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2024/07/070967
Enrollment
11
Registered
2024-07-22
Start date
Unknown
Completion date
Unknown
Last updated
2024-08-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: K081- Complete loss of teeth

Interventions

Intervention1: Border moulding using functional swallow method and green stick impression compound.: In functional swallow method, patients inherent swallowing force is used to record the posterior p

Sponsors

Dr Surabhi S
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: 1. Patients with completely edentulous maxilla. 2. Patient willing to give informed consent. 3. Patients between 40-70 years of age. 4. Patients with class I & II residual alveolar ridge in maxilla (according to ACP classification) 5.Patients with firm mucosa all over the denture bearing area without any signs of inflammation or ulceration or hyperplasia.

Exclusion criteria

Exclusion criteria: 1.Patients with severe undercuts, bony exostosis and tori. 2.Patients with extreme high palatal vault. 3.Patients with resorbed residual ridge. 4.Patients with poor neuromuscular control.

Design outcomes

Primary

MeasureTime frame
To evaluate and compare the retention of complete denture bases with posterior palatal seal registrations with conventional and functional swallow methods using heavy bodied polyvinyl siloxane impression material. Timepoint: At baseline , 7days

Secondary

MeasureTime frame
To evaluate & compare the retention of complete denture bases fabricated with posterior palatal seal registrations made using low fusing impression compound & heavy bodied polyvinyl siloxane impression material.Timepoint: At base line , 7 days;To evaluate & compare the retention of complete denture bases with posterior palatal seal registrations with conventional & functional swallow methods using low fusing impression compoundTimepoint: At base line ,7 days

Countries

India

Contacts

Public ContactDr Deviprasad Nooji

KVG Dental College and Hospital

devinooji@gmail.com9448688673

Outcome results

None listed

Source: CTRI (via WHO ICTRP) · Data processed: Feb 4, 2026