Skip to content

usage of ultrasound to determine size of paediatric endotracheal tube

Ultrasonographic Measurement of Subglottic Diameter for Paediatric Endotracheal Tube Size Selection and its comparison with age based formulae: an observational prospective study - NIL

Status
Active, not recruiting
Phases
Phase 3Phase 4
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2023/12/060899
Enrollment
35
Registered
2023-12-28
Start date
Unknown
Completion date
Unknown
Last updated
2024-01-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: R688- Other general symptoms and signs

Interventions

Intervention1: medical device (ultrasound): Ultrasonographic Measurement of Subglottic Diameter of paediatric patients Intervention2: MEDICAL DEVICE(ULTRASOUND): Ultrasonographic Measurement of Subglo

Sponsors

dr charulata deshpande
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: - Weight more than 10kg - Patients requiring orotracheal intubation for anaesthesia - Patients willing to give informed written consent - American Society of Anaesthesiologists physical Status I and II patients

Exclusion criteria

Exclusion criteria: - Patient refusal - Emergency surgery - Head and neck anatomical abnormality - Restricted mouth opening - Soft tissue swelling over neck - Cervical spine injury, or abnormality - Any other contraindication to intubation - Patients requiring rapid sequence intubation. - Uncooperative patients - previous histories of tracheal and laryngeal pathologies, such as tracheostomy; previous surgery involving upper airway and any obvious scars

Design outcomes

Primary

MeasureTime frame
to assess the SGD ultrasongraphically and compare it with age based formulae;as a true reflection of the correct ETT sizeTimepoint: its a single point measurement, which be less than a minute after giving muscle relaxant

Secondary

MeasureTime frame
-To assess the usefulness of US by reintubation attempts with different size of ETT due to unacceptable leak. -To compare US predicted ETT size with age based formulae Timepoint: Duration of the study will cease once the subglottic diameter is measured which may not be more than 15 minutes

Countries

India

Contacts

Public Contactdr jain roma

TOPIWALA NATIONAL MEDICAL COLLEGE AND BYL NAIR CHARITABLE HOSPITAL

jain.roma6@gmail.com8097671274

Outcome results

None listed

Source: CTRI (via WHO ICTRP) · Data processed: Feb 4, 2026