Skip to content

Evaluation of a pulse oximetry monitor index to assess titration of intraoperative fluids in spontaneously breathing anaesthetized children

Evaluation of Plethysmography Variability Index (PVI) to assess fluid responsiveness in spontaneously breathing anaesthetized children - nil

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
CTRI
Registry ID
CTRI/2023/11/059945
Enrollment
54
Registered
2023-11-17
Start date
Unknown
Completion date
Unknown
Last updated
2023-12-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: Z409- Encounter for prophylactic surgery, unspecified

Interventions

Intervention1: Fixed fluid bolus of 10ml/kg, Transthoracic echo: After securing the supraglottic airway device, all patients will receive single-shot caudal epidural analgesia with 0.2% ropivacaine as

Sponsors

Postgraduate Institute of Medical Education and Research Chandigarh
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: Children scheduled for elective surgical procedures under general anaesthesia with a supraglottic airway device and caudal block.

Exclusion criteria

Exclusion criteria: -Known congenital heart disease -Comorbid respiratory illness. -Preoperative total gut irrigation or intravenous fluids -Refusal of consent -Allergic to anaesthetic agents

Design outcomes

Primary

MeasureTime frame
Predictability of Plethysmographic Variability index (PVI) as reliable parameter for fluid responsiveness in spontaneously breathing anaesthetized childrenTimepoint: All the measurements are taken after anaesthesia induction before starting of surgery : baseline measurements taken just after insertion of supraglottic airway device, then second set of measurements are taken 1 minute after passive leg raising, third set of measurements done after 10ml/kg fluid bolus over 10 minutes, fourth set of measurements done one minute after repeating passive leg raising , after 4 set of measurements surgery will bestarted

Secondary

MeasureTime frame
Predictability of passive leg raising as reliable parameter for fluid responsiveness in spontaneously breathing anaesthetized childrenTimepoint: All the measurements are taken after anaesthesia induction before starting of surgery : baseline measurements taken just after insertion of supraglottic airway device, then second set of measurements are taken 1 minute after passive leg raising, third set of measurements done after 10ml/kg fluid bolus over 10 minutes, fourth set of measurements done one minute after repeating passive leg raising , after 4 set of measurements surgery will be started

Countries

India

Contacts

Public ContactPreethy J Mathew

Postgraduate Institute of Medical Education and Research, Chandigarh

tjpreethy@gmail.com9417800203

Outcome results

None listed