Skip to content

Assessment of dental implant stability in poor quality bone with intraoral welding

Comparative evaluation of implant stability in welded immediate implant with and without bicortical anchorage: A randomized controlled trial

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2023/03/050514
Enrollment
22
Registered
2023-03-09
Start date
Unknown
Completion date
Unknown
Last updated
2024-05-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: K053- Chronic periodontitis Health Condition 2: K029- Dental caries, unspecified Health Condition 3: K089- Disorder of teeth and supporting structures, unspecified

Interventions

Intervention1: MONOCORTICAL ANCHORAGE: Immediate implant placement with monocortical anchorage, intraoral welding and immediate prosthetic rehabilitation is 0(Baseline), 3 months, 6 months and 1 yr Co

Sponsors

Dr Akshi
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: 1. 40 to 60 years 2. Multiple posterior teeth indicated for extraction in bilateral posterior maxilla. 3. Adequate bone in width and height for insertion of an implant with 10-11mm length and 4-5 mm diameter 4. Adequate interocclusal space of 10mm 5. Group functional occlusion

Exclusion criteria

Exclusion criteria: 1. Patient unable to give written informed consent to participate 2. Opposing dentitions other than natural teeth. 3. Radiation therapy and chemotherapy in the craniofacial region within the previous 12 months 4. If they smoked >10 cigarettes/day, used tobacco or tobacco products within past one week. 5. Systemic diseases that could compromise osseointegration. 6. Patients with history of bone augmentation by artificial graft, in the position of proposed implant site. 7. Patients with pacemakers.

Design outcomes

Primary

MeasureTime frame
To compare the crestal bone loss in radiographic intervention through paralleling technique of intraoral radiography in intraoral welded, immediate implant in low density bone with and without bicortical anchorage. Timepoint: Baseline is considered as the time of immediate implant placement, intraoral welding and immediate prosthetic rehabilitation. Time Points are 0(Baseline), 3 months, 6 months and 1 year

Secondary

MeasureTime frame
To assess patient satisfaction using OHIP-14 questionnaire in intraoral welded, immediate implant in low density bone with and without bicortical anchorageTimepoint: Baseline is considered as the time of immediate implant placement, intraoral welding and immediate prosthetic rehabilitation. Time Points are 0(Baseline), 3 months, 6 months and 1 year;To compare the ISQ Value by Resonance Frequency Analysis (RFA)in intraoral welded, immediate implant in low density bone with and without bicortical anchorage. Timepoint: Baseline is considered as the time of immediate implant placement, intraoral welding and immediate prosthetic rehabilitation. Time Points are 0(Baseline), 3 months, 6 months and 1 year

Countries

India

Contacts

Public ContactDr LAKSHYA KUMAR

King Georges Medical University U.P. Lucknow.

lakshya79@yahoo.com9412119778

Outcome results

None listed

Source: CTRI (via WHO ICTRP) · Data processed: Feb 4, 2026