Skip to content

A COMPARATIVE STUDY BETWEEN NEW AIRWAY AIRWAY SECURING DEVICES TO OTHER AIRWAY SECURING DEVICE IN PATIENT WITH NORMAL AIRWAY WHO ARE BEING UNDERGOING FOR ELECTIVE OPERATION.

A comparative study of intubation parameters between Blockbuster LMA and C-MAC video laryngoscope in a patient with normal airway undergoing elective surgery

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2021/08/035862
Enrollment
204
Registered
2021-08-24
Start date
Unknown
Completion date
Unknown
Last updated
2021-11-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: O- Medical and Surgical

Interventions

Intervention1: BLOCKBUSTER LMA : INTUBATION WILL BE DONE INTRAOPERATIVELY AND TIME DURATION OF INSERTION , NUMBER OF ATTEMPTS AND ANY POST OPERATIVE COMPLICATION WILL BE ASSESSED Control Intervention

Sponsors

All India Institute of Medical Sciences Patna
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: ASA I and ASA II BMI - Posted for elective surgery in routine operation theatre

Exclusion criteria

Exclusion criteria: ASA III and IV Gastroesophageal reflux Age 55 years Mallampatti grading III , IV Any obstructive airway pathology andcervical spine abnormality, restricted neck movement Patient not giving consent for study

Design outcomes

Primary

MeasureTime frame
1.To measure ease of intubation in three attempts Timepoint: by grading 1-intubation with no resistance in one attempt in airway tract 2- intubation with 1 external manipulation to larynx 3- intubation with 1 external manipulation to larynx 4- 3 attempts for intubation with external manipulation with or without use of adjuncts . 5 - 3 attempt for intubation with external manipulation to larynx with the use of adjuncts 6:-Other technique used for intubation after failed attempts or intubation done by experienced anaesthetics

Secondary

MeasureTime frame
1.TIME OF INTUBATION 2.NUMBER OF ATTEMPTS 3. For Post operative complication Timepoint: 1.time interval between holding the airway device to confirmation of correct placement by square wave capnogram appearance will be noted. It will be recorded in seconds 2.3 attempts will be considered as failed intubation 3 a. Sore throat before shifting from recovery room and after 24 hours b.By presence of blood stain in endotracheal tube just after extubation

Countries

India

Contacts

Public ContactDR UMESH KUMAR BHADANI

AIIMS PATNA

umeshbhadani@gmail.com8969169123

Outcome results

None listed