Skip to content

Comparing two different techniques of nasal intubation.

Comparison of Cuff Inflation and Conventional Technique for Nasotracheal Intubation using C-MAC Video Laryngoscope. A Prospective Randomised Controlled Trial.

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2020/12/029692
Enrollment
106
Registered
2020-12-09
Start date
Unknown
Completion date
Unknown
Last updated
2021-11-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: 8- Other Procedures

Interventions

Intervention1: ET tube Cuff inflation to guide tube from oropharynx into glottis in Nasotracheal intubation till tube crossed beyond vocal cord: Comparison of two different techniques Cuff inflation

Sponsors

All India Institute of Medical Sciences
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: 1 Patient scheduled for elective surgery requiring nasal intubation 2 American Society of Anaesthesiologists (ASA) physical status 1-2

Exclusion criteria

Exclusion criteria: 1 Patient refusal 2 known difficult Airway 3 Patient with mouth opening 4 Patient difficult to mask ventilate 5 History of larynx surgery or larynx radiotherapy 6 Anticipated esophago-tracheal reflux 7 mallampati view 3 or 4 8 Frequent episodes of epistaxis or bleeding tendency 9 patients with significant systemic disease 10 Patient having Contraindications for NTI

Design outcomes

Primary

MeasureTime frame
Primary outcome of our study is Time taken for ETT placement(defined as time taken after the confirmation of tip of endotracheal tube in nasopharynx by C-MAC video laryngoscope to the appearance of three successive end tidal CO2 waveforms.Timepoint: Primary outcome of our study is Time taken for ETT placement(defined as time taken after the confirmation of tip of endotracheal tube in nasopharynx by C-MAC video laryngoscope to the appearance of three successive end tidal CO2 waveforms by the end of 1 minute, beyond one minute attempt is considered a failure.

Secondary

MeasureTime frame
1 Type and number of manoeuvres (M1-M4) used 2 Hemodynamic response to intubation 3 Complication if anyTimepoint: Hemodynamic parameters SpO2,HR and BP measured at pre-op,1,2,3,4,5,10,15 minutes after intubation

Countries

India

Contacts

Public ContactDr Sangamala Venkata Prem Kumar

All India Institute of Medical Sciences Jodhpur

drrakeshspmc@gmail.com9460429221

Outcome results

None listed