Self/ Home measurement of Intra-ocular pressure by Icare Home Device as compared to professional tonometry

Comparative Study of Intraocular Pressure Measurements Obtained by Self/Home Tonometer â?? Icare Home (TA022) with that of Goldmann Applanation Tonometer and Icare (IC100)

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
CTRI
Registry ID
CTRI/2019/11/022125
Enrollment
43
Registered
2019-11-22
Start date
Unknown
Completion date
Unknown
Last updated
2021-11-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: H401- Open-angle glaucoma Health Condition 2: H408- Other glaucoma Health Condition 3: H402- Primary angle-closure glaucoma

Interventions

Control Intervention1: IOP measurement by patient: 1 device used to measure self IOP by patients - Icare Home (TA022), Control Intervention2: IOP measurement by caregiver: 1 device used to measure IOP

Sponsors

Isha Gupta
Lead Sponsor
Aravind Eye Hospital
Collaborator

Eligibility

Inclusion criteria

Inclusion criteria: Patient diagnosed with primary or secondary glaucoma presenting with his/her caregiver, wherein both are willing to give informed written consent

Exclusion criteria

Exclusion criteria: 1. Patients with any corneal pathology including corneal edema. 2. Best corrected near visual acuity of more than N.8 or far acuity of more than 6/9. 3. Patients with learning disability. 4. Patients with motor disability/neurological disease â?? ocular and systemic. (Parkinsonâ??s disease, muscular dystrophies, hand tremors, myasthenia gravis) 5. Patients who cannot be examined on slit lamp due to postural deformities. 6. Patients with any macular pathology. 7. Eye with any active infection or inflammation (acute red eye). 8. History of or any ocular surgery less than 6 months before the date of recruitment. 9. History of any corneal surgery irrespective of time since surgery.

Design outcomes

Primary

MeasureTime frame
1. Inter-device agreement between Icare Home(TA022) and Goldmann applanation tonometer. 2. Inter-device agreement between Icare Home(TA022) and Icare (ic100) tonometer. 3. Inter-user agreement of Icare Home(TA022) between patient and caregiverTimepoint: May 2019

Secondary

MeasureTime frame
Ease of use of Icare home Device by patients and their caregiversTimepoint: On the day of enrollment

Countries

India

Contacts

Public ContactIsha Gupta

Aravind Eye Hospital

skavitha.shree@gmail.com9894611575

Outcome results

None listed