A Clinical trial to evaluate success and mobility between two types of orthodontic miniimplants ( surface treated and non surface treated ) used to get support in fixed orthodontic treatment

Osseointegration and stability of surface treated and non surface treated Orthodontic miniimplants.

Status
Active, not recruiting
Phases
Phase 4
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2019/10/021718
Enrollment
8
Registered
2019-10-18
Start date
Unknown
Completion date
Unknown
Last updated
2021-11-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Interventions

Intervention1: Surafce treated orthodontic miiimpants: Bioray Orthodontic miniimplants ( A1 miniimplants ) that are acid etched with Hcl and H2 so4 and sandbasted with alumina ( 250 - 500 micrometers)

Sponsors

Self supported study Dr R Janani
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: 1. Patients who underwent therapeutic extraction of all the four first premolars as part of fixed orthodontic treatment 2.Patients requiring maximum anchorage, with 75 % to 100 % of space closure for retraction of anterior segment 3.Patients treated with 0.22 MBT prescription 4. Aligning and leveling phase should have been completed 5. No other anchorage preservation methods used for the study

Exclusion criteria

Exclusion criteria: 1.Presence of any systemic disease 2. Presence of any local bone pathology evident on a OPG 3. Patients allergic to titanium

Design outcomes

Primary

MeasureTime frame
Comparison of stability between surface treated and non surface treated orthodontic miniimplantsTimepoint: Insertion torque will be measured at the time of insertion of the miniimplants,recorded at 0 sec ( 0 turns), 4 sec( 2 turns) and 8 sec( 4 turns) at the beginning of retraction, Removal torque will be measured at the time of removal of the miniimplats ,recorded at 0 sec ( 0 turn), 1 sec( 1 turn ), and 2 sec( 2 turns) after the 6 months retraction period. The histomorphometric analysis will be done once the miniimplants are removed under a Scanning electron microscope

Secondary

MeasureTime frame
Bone to implant contact by histomorphometric analysisTimepoint: Time when retraction is complete