Compare visual fields with New Elisar perimeter device with Humphrey perimeter with new software algorithm

Comparison of the New Elisar Fast Algorithm with Swedish Interactive thresholding Algorithm fast

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
CTRI
Registry ID
CTRI/2019/05/019204
Enrollment
100
Registered
2019-05-20
Start date
Unknown
Completion date
Unknown
Last updated
2021-11-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: H409- Unspecified glaucoma

Interventions

Control Intervention1: NA: NA

Sponsors

Dr Amar Agarwal
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: Controls: 1.Cup disc ratio less than 0.5 (intraocular difference of 0.2 mm) 2.IOP 3.The normal result of Glaucoma Hemifield test in HFA 30-2 SITA fast Glaucoma and non-glaucomatous field loss: 1. Glaucoma is defined as IOP greater than 21 mmHg or intraocular difference in IOP more than 3mmHg and Cup disc ratio more than 0.5, and the intraocular difference in a cup-disc ratio less than more than 0.2. 2.A positive report of the SITA standard with Humphrey visual field analyzer. 3. The best corrected visual acuity should be better than or equal to 6/12. 4. Spherical correction should be

Exclusion criteria

Exclusion criteria: Exclusion criteria: 1. Fixation losses, false positive and false negative > 20% will be excluded from the study. 2. The reports with significant lid artifact will be excluded from the study. The lid artifact is defined as the density of the defect greater than or equal to 11 decibels (dB) for a single test location or greater than or equal to 7 dB for two adjacent test locations according to the pattern deviation from age-corrected normal values. Second, the defect must involve loci between 20° and 30°. 3. Patients who had undergone ocular surgeries (other than cataract surgery), patients with ocular disease, amblyopia, neurological disorders will be excluded from the study. 4. Patients using a miotic drug will be excluded from the study.

Design outcomes

Primary

MeasureTime frame
To establish a correlation between Elisar and Humphrey visual field analyzer. If both the devices correlate well, Elisar can be used in place of Humphrey due its portable nature.Timepoint: 15 days

Secondary

MeasureTime frame
Glaucoma can be picked up at an early stage due to its affordability and portable nature.Timepoint: 6 months