Skip to content

A research to compare two medical devices used for securing the airway of the patients under general anaesthesia in laparoscopic surgeries of the gall bladder stones.

Comparison of ventilatory efficacy and airway dynamics between BlockBuster supraglottic airway device and endotracheal tube in patients undergoing laparoscopic cholecystectomy: a randomized controlled trial

Status
Active, not recruiting
Phases
Phase 4
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2019/04/018497
Enrollment
60
Registered
2019-04-09
Start date
Unknown
Completion date
Unknown
Last updated
2021-11-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Health Condition 1: K802- Calculus of gallbladder without cholecystitis

Interventions

Intervention1: BlockBuster laryngeal mask airway: Airway device to be used for securing airway during general anaesthesia. Control Intervention1: Endotracheal tube: Airway device to be used for securi

Sponsors

GMCH
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: ASA 1 or 2. Patients scheduled for elective laparoscopic cholecystectomy surgery under general anaesthesia.

Exclusion criteria

Exclusion criteria: Patients with anticipted difficult airway. Patients with upper respiratory tract infection. Patients with increased risk of regurgitation and aspiration of gastric contents. Patients with a body mass index > 35kg/m2. Patients with past history of radiotherapy to the neck involving the hypopharynx. Pregnant patients.

Design outcomes

Primary

MeasureTime frame
Ventilatory parameters (peak airway pressure, plateau pressure, mean airway pressure, inspiratory and expiratory tidal volume, inspiratory and expiratory minute ventilation, inspiratory expiratory ratio, compliance, airway resistance,end tidal carbon dioxide)Timepoint: After intubation/Supraglottic airway device placement, before carboperitoneum, after carboperitoneum, at 10 minutes after position, after release of carboperitoneum.

Secondary

MeasureTime frame
Hemodynamic parameters (non invasive blood pressure[systolic, diastolic, mean arterial pressure], heart rate, oxygen saturation.Timepoint: Baseline, after induction, after intubation/Supraglottic airway device placement, before carboperitoneum, after carboperitoneum, at 10 minutes after position, after release of carboperitoneum, after extubation/Supraglottic airway device removal

Countries

India

Contacts

Public ContactDr Lakesh K Anand

Government Medical College and Hospital Sector 32 Chandigarh

lkanand11@gmail.com9646121522