Skip to content

A research to evaluate and compare two medical devices ( Air Q-SP and Proseal laryngeal mask airway) use to ventilate the patients undergoing elective surgery under general anaesthesia.

Comparative evaluation of Air-Q SP and Proseal Laryngeal Mask Airway in patients undergoing elective surgery under general anaesthesia

Status
Active, not recruiting
Phases
Phase 4
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2018/02/011737
Enrollment
90
Registered
2018-02-06
Start date
Unknown
Completion date
Unknown
Last updated
2021-11-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Interventions

Intervention1: Air-Q SP: will be used to maintain the patency of airway during general anaesthesia. will be inserted only once after induction of anaesthesia. Control Intervention1: Proseal Laryngeal

Sponsors

Government Medical College and Hospital Sector Chandigarh
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: Inclusion criteria 1.Age group between 18 to 60 years 2.American Society of Anaesthesiologist (ASA) physical status I and II. 3.Patients scheduled for elective surgery under general anaesthesia (Duration of surgery 2 ± 0.5 hrs)

Exclusion criteria

Exclusion criteria: The following patients will be excluded from the study. 1.Patients with anticipated difficult airway (Airway Difficulty Score >8). 2.Patients with upper respiratory tract infection 3.Patients with increased risk of regurgitation and aspiration of gastric content 4.Patients with a body mass index (BMI) > 35 kg.m.-2 5.Patients with past history of radiotherapy to the neck involving the hypopharynx 6.Patients undergoing surgeries involving neck and oral cavity 7.Pregnant patients.

Design outcomes

Primary

MeasureTime frame
To compare the oropharyngeal leak pressure of Air-Q SP and Proseal Laryngeal Mask Airway in patients undergoing elective surgery under general anaesthesia.Timepoint: immediately after the placement of device

Secondary

MeasureTime frame
To compare the overall efficacy of Air-Q SP and Proseal laryngeal mask airway by comparing the ease of insertion, fiberoptic visualization, hemodynamic and ventilatory parameters,in patients undergoing elective surgery under general anaesthesiaTimepoint: 1. Ease of insertion, fiberoptic visualization- will be observed immediately after placement of device. 2. Hemodynamic and ventilatory parameters- at 1, 2, 3, 4, 5 and 10 minutes

Countries

India

Contacts

Public ContactDr Lakesh K Anand

Government Medical college and hospital sector 32, Chandigarh

lkanand11@gmail.com9646121522

Outcome results

None listed

Source: CTRI (via WHO ICTRP) · Data processed: Feb 4, 2026