A research to compare the use of two medical devices (C- MAC D-Blade videolaryngoscope and McCoy laryngoscope), in patients with restricted neck mobility.

A comparative evaluation of C-MAC D-Blade videolaryngoscope and McCoy laryngoscope in patients undergoing tracheal intubation with simulated restricted neck mobility.

Status
Active, not recruiting
Phases
Phase 4
Study type
Interventional
Source
CTRI
Registry ID
CTRI/2016/08/007139
Enrollment
54
Registered
2016-08-03
Start date
Unknown
Completion date
Unknown
Last updated
2021-11-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Interventions

Intervention1: C-MAC D-Blade videolaryngoscope: Will be used for oral endotracheal intubation during general anaesthesia Control Intervention1: McCoy laryngoscope: Will be used for oral endotracheal i

Sponsors

Director Principal of Government Medical College and Hospital
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: 1. Age group of 18 to 60 years 2. ASA (American Society of Anaesthesiologists) physical status I and II 3. Patients undergoing elective surgery requiring endotracheal intubation under general anaesthesia

Exclusion criteria

Exclusion criteria: 1. Morbid obesity 2. Patients with anticipated difficult airway[Airway Difficulty Score >8] 3. Patients at increased risk of pulmonary aspiration such as gastroesophageal reflux disease(GERD), peptic ulcer disease 4. Previous upper gastrointestinal surgery 5. Pregnancy 6. Coagulopathy or history of anticoagulant use 7. Cardiorespiratory or cerebrovascular disease 8. Cervical spine pathology

Design outcomes

Primary

MeasureTime frame
To evaluate and compare C-MAC D-Blade videolaryngoscope with McCoy laryngoscope for time taken for tracheal intubation in patients with simulated restricted neck mobility undergoing elective surgery under general anaesthesia.Timepoint: Outcome (TTI) will be assessed at point of appearance of square wave capnograph on monitor after the introduction of device in mouth and subsequent endotracheal tube placement. [TTI- defined as time of introduction of device in mouth to the confirmation of endotracheal tube placement by a square wave capnograph on the monitor].

Secondary

MeasureTime frame
To Compare the: 1. Laryngeal view 2. Number of attempts 3. Heart Rate (HR),Non-Invasive Blood Pressure (Systolic, Diastolic and Mean), Continuous electrocardiogram (ECG), oxygen saturation (SPO2) and End Tidal carbon dioxide level (ETCO2). 4. Intraoperative findings and post operative adverse eventsTimepoint: 1. Laryngeal view: immediately after introduction of laryngoscope 2. HR, NIBP, ECG, SPO2 and ETCO2: just before intubation, immediately after intubation, 1minute interval for next 5 minutes after intubation, 5 minute interval till 15 minutes after intubation 3.Intra/postoperative findings and adverse events: immediately after endotracheal intubation, immediately after extubation of tracheal tube, 2 hours after extubation of tracheal tube, 12 hours after extubation of tracheal tube