Skip to content

COntinuous fetal heart rate Monitoring using non-invasive Fetal electrocardiographY 3 (COMFY 3)

COntinuous fetal heart rate Monitoring using non-invasive Fetal electrocardiographY 3 (COMFY 3)

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ANZCTR
Registry ID
ACTRN12625001049460
Acronym
COMFY3
Enrollment
69
Registered
2025-09-24
Start date
2025-10-16
Completion date
2027-07-01
Last updated
2026-09-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Brief summary

The purpose of this research is to compare the new Kali Monitoring System to standard-of-care cardiotocography, and evaluate its reliability, safety and usability.

Interventions

The Kali Monitoring System is a new device that is able to detect fetal heart rate, maternal heart rate and uterine activity using non-invasive electrocardiogram (ECG) technology. In this study we seek to evaluate the reliability, safety and user experience of the Kali Monitoring System for monitoring fetal heart rate, maternal heart rate and uterine activity. We plan to recruit a total of 100 women. Participants will also receive a questionnaire about fetal monitoring prior to having the Kali

The Kali Monitoring System is a new device that is able to detect fetal heart rate, maternal heart rate and uterine activity using non-invasive electrocardiogram (ECG) technology. In this study we seek to evaluate the reliability, safety and user experience of the Kali Monitoring System for monitoring fetal heart rate, maternal heart rate and uterine activity. We plan to recruit a total of 100 women. Participants will also receive a questionnaire about fetal monitoring prior to having the Kali Monitoring System applied and their experience with participation at the conclusion. Antenatal participants will also be asked to complete The State Trait Anxiety Inventory and a System Usability Scale. Midwives will take notes on usability issues encountered during use. Once the informed consent is signed, participants are asked to sit on a reclined chair or lie on a hospital bed for application of the Kali Monitoring System and CTG (cardiotocography - the current clinical standard-of-care). The researcher prepares the patient's skin by cleaning it and by using skin preparation gel. The researcher proceeds with setting up the Kali Monitoring System including connection to the Kali Cloud and Kali Application on a smart phone, in parallel with setting up the standard of care CTG. With this setup, data is collected with both devices, while the Kali Monitoring System performs an electrode connection and signal quality check (screening test). This step may take up to 5 minutes. If the electrode connection check fails or the CTG does not capture the maternal heart rate or fetal heart rate signals, the measurement setup is adjusted as needed (up to three attempts are allowed). A participant is considered included for data analysis when the electrode connection and signal quality screening test gives a successful result (performed automatically by the Kali Monitoring System) and at least 30 minutes of data is collected from both the Kali Monitoring System and standard-of-care CTG. Recordings will be taken from both the Kali Monitoring System and CTG for at least 30mins or the duration of the CTG in pregnancy and/or labour and birth. For participants recruited in labour application and insertion of a fetal scalp electrode and intrauterine pressure catheter will be required (if not contraindicated). If a potential labour participant does not consent or has contraindications to the fetal scalp electrode and/or intrauterine pressure catheter they will be excluded from participation in the trial. A participant will only be recruited once over the duration of the study.

Sponsors

Kali Healthcare
Lead SponsorCommercial sector/Industry

Study design

Allocation
Non-randomised trial
Primary purpose
Diagnosis

Eligibility

Sex/Gender
All
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Pregnant women >/or equal to 18 years old Gestational age >/or equal to 32 weeks and 0 days Singleton pregnancy Ability to read and understand English Willingness to participate in the study Clinically indicated to have CTG monitoring

Exclusion criteria

Implanted pacemaker or any other implanted electrical device Plurality higher than 1 History of allergies to skin adhesives Irritated or lesioned skin at the electrodes locations Contraindication to the use of CTG Contraindication to the use of fetal scalp clip or intrauterine pressure catheter in labour

Outcome results

None listed

Source: ANZCTR · Data processed: Sep 19, 2026