Brief summary
The proposed study will be a prospective, observational, non-intervention study that will collect clinical ocular measurements from a range of participants including those with healthy and diseased retinas to allow comparison of the Cylite Hyperparallel Optical Coherence Tomographer (HP-OCT) with the Heidelberg Spectralis Spectral-Domain Optical Coherence Tomographer (SD-OCT). The main objective of this study is to evaluate the validity and repeatability of the retinal layer segmentation of images acquired with the HP-OCT.
Interventions
A total of 90 eyes (30 healthy (normal) eyes, 30 glaucomatous eyes and 30 diseased retina eyes) will be analysed within this study. A wide refractive range of normal participants will be sought with particular focus on recruiting a number of high myopes (>5 D). In order to achieve this, it is anticipated that a total of 100 participants aged 18 years and over will be screened for this study. Only one eye of an individual will be measured if they meet the inclusion criteria. Following the study screening, if both eyes of an individual meet the inclusion criteria, the eye to be tested will be determined from a randomisation list using a Latin Square design. The instrument testing order for each participant will also be randomised. After informed consent process and screening examination, each eligible subject will undergo the following scans. On Cylite's HP-OCT, • One valid biometry scan will be taken. • Three valid retinal images will then be taken for two separate posterior eye modes. - The first employs a central fixation target and focusses on the macula - The second utilises a nasal fixation target focusing on the optic nerve head. • An additional scan will be captured using the macula scanning protocol with a varied working distance. For example, the additional image may be taken in positive delay when the three original images may have been captured in negative delay. On Spectralis, • Three valid horizontal macula scans will be collected. The macula scans will be volumetric and will match the parameters of the HP-OCT as closely as possible. • Two optic nerve head scanning protocols will be implemented on the Spectralis SD-OCT instrument. - Firstly, 3 valid radial circle maps will be captured which consist of 24 radial scans and three circle scans of varying diameter. - Secondly, 3 optic nerve head volume scans will be captured. All scans are non-contact and non-invasive. The HP-OCT and Spectralis are both imaging OCT devices. They are not applied to a subject, rather a subject is imaged on these devices by placing their chin on a chin rest and the forehead on a forehead rest and a non-invasive image is taken. Both devices utilize spectral domain (SD-OCT) OCT technology, the key different between the two devices is the HP-OCT includes micro-optics to create a parallel grid of 1008 beamlets to capture an image whereas the Spectralis uses just one scanning beam. All eligible subjects will receive the same required scans on all the devices as described above. All scans are completed in a single imaging session. Imaging time will be no more than 20min at each device, this time allows for the subject to sit back and take the time they need in between the imaging. The repeatability of HP-OCT measurements will be characterised and the agreement of the measurements between HP-OCT and Spectralis will be studied for the following segmentation parameters. • Macular - ETDRS thickness maps (centred at the fovea and oriented horizontally) each ETDRS quadrant for the mean (+/-SD) retinal nerve fibre layer (RNFL), combined ganglion cell and inner plexiform layer (GCL+IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL), retinal pigment epithelium (RPE) as well as total retinal thickness. • Optic Disc - Optic nerve head retinal nerve fibre layer thicknesses within a peripapillary zone of 3.45 mm diameter; Average RNFL thickness as well as quadrant-specific (superior, inferior, temporal and nasal) RNFL thicknesses; Macula and GC-IPL thicknesses within an elliptical annulus area around the fovea; Optic nerve head parameters including cup-disc ratios (vertical, horizontal and mean) as well as minimum rim-width (superior, inferior, nasal, temporal and overall). The user interface of each device provides the user with quality indicators to guide the user on the scan quality. These indicators are outlined within the user manual of each device and will make up part of the training for the user prior to the study commencing, The different scan locations (e.g. macular) needed for this study are also outlined in the user interface and will again be addressed during the training to ensure the scan protocols are met.
Sponsors
Eligibility
Inclusion criteria
o Participants with normal healthy eyes apart from specific recruitment categories o Participants will have best corrected visual acuity (logMAR 0.30, 6/12 or better in each eye), unless they fall into the specific recruitment categories of glaucoma or diseased retina o Approximately equal numbers of male and female participants will be sought To assess for Glaucomatous and Diseased retina eyes the following tests will be performed during screening: o Case history will be taken to record medical and ocular history and concomitant medications o Anterior eye examination - slit lamp biomicroscopy including cataract grading (LOCSIII) and angle assessment o Posterior pole eye examination using slit-lamp biomicroscopy to observe and record the health of the optic nerve and macula. Retinal images will also be captured using a standard retinal camera which will be used as part of the subject qualification and data analysis.
Exclusion criteria
o No history of ocular injury in the past 12 weeks o No use of lubrication within an hour of testing o No contact lens wear on the testing day o No active ocular infection or inflammation o No previous ocular surgery apart from LASIK or cataract surgery o No strabismus o No ocular pathology (anterior or posterior) which is likely to affect the participants ability to fixate on the instrument’s fixation target (and therefore affect their ability to have high quality measurements obtained)