Feasibility of a New Medtronic Experimental Automated Insulin Delivery (Artificial Pancreas) System

Evaluation of the Feasibility of a Novel Medtronic Experimental Automated Insulin Delivery System In Adults With Type 1 Diabetes

Status
Not yet recruiting
Phases
Unknown
Study type
Interventional
Source
ANZCTR
Registry ID
ACTRN12623001076662
Enrollment
15
Registered
2023-10-09
Start date
2023-11-01
Completion date
2023-11-30
Last updated
2023-10-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Brief summary

Automated insulin delivery (artificial pancreas systems) can help to improve management of glucose levels in people living with type 1 diabetes while at the same time reducing the heavy intellectual and psychological burden of care. However, the success of closed-loop/artificial pancreas devices moving forward relies upon their ease of use and ability to reduce and relieve the burden of living with type 1 diabetes. Current commercially available automated insulin delivery devices represent hybrid closed loop (HCL) systems requiring the user to initiate boluses of insulin to address meal-time insulin requirements. Eliminating a requirement for the user to bolus for meals, without compromising glucose control, would substantially reduce the burden of care on people living with type 1 diabetes. The Medtronic MinimedTM NMX-AID system is a new-generation closed loop system (artificial pancreas) similar to an existing, commercially available Medtronic insulin pump, the MiniMedTM 780G Pump, and has the capability to operate in Manual Mode (also referred to as open loop) or with the SmartGuard feature active (also referred to as closed loop). However, the NMX-AID system differs from the Minimed 780G Pump as it contains modifications to the closed loop algorithm, including the addition of a Pump Start feature that enables the user to skip the 48-hour warm-up to enter SmartGuard and also allows automatic delivery of meal boluses without user input or acknowledgement. These new advances have significant potential to improve the experience of using closed-loop technology. The aim of this study is to demonstrate feasibility of the device, and to generate initial data to evaluate safety, user acceptance and system efficacy of the Medtronic Minimed NMX-AID system in adults with type 1 diabetes. We believe that the Medtronic Minimed NMX-AID system will be feasible and safely improve user satisfaction in people with type 1 diabetes without sacrifices in glucose control compared with insulin delivery with the MiniMed 780G system.

Interventions

The purpose of this research study is to demonstrate feasibility and to generate initial data to evaluate safety, user acceptance and system efficacy of the Novel Medtronic Experimental Automated Insulin Delivery (NMX-AID) system in adults with type 1 diabetes. The NMX-AID system includes a Medtronic 780G insulin pump with updated software, a factory-calibrated ‘DS5’ continuous glucose sensor, and an extended wear infusion set. A sequential before and after study design will be undertaken in fou

The purpose of this research study is to demonstrate feasibility and to generate initial data to evaluate safety, user acceptance and system efficacy of the Novel Medtronic Experimental Automated Insulin Delivery (NMX-AID) system in adults with type 1 diabetes. The NMX-AID system includes a Medtronic 780G insulin pump with updated software, a factory-calibrated ‘DS5’ continuous glucose sensor, and an extended wear infusion set. A sequential before and after study design will be undertaken in four stages, with data analysis occurring to compare data between stages. User perception of the technology will be assessed at the end of Run-in and at the end of each study stage with a validated questionnaire (Insulin Delivery System Rating Questionnaire-Short Form). Continuous glucose sensor data and insulin delivery data will be collected from the study devices throughout the study and monitored for safety and for adherence by the study staff/diabetes educators. A semi-structured interview to assess participants’ perceptions of NMX-AID will be implemented at the end of the study. Participation in this research will occur over approximately 12-16 weeks. Fifteen participants with type 1 diabetes, with at least three months experience with the Minimed 780G will be recruited. Following informed consent, a baseline clinical history will be obtained, and physical examination performed. Adjustment of all device settings may occur throughout all study stages. Device education and review will be performed by accredited diabetes nurse educators. The schedule of the four stages is as follows, with further details regarding study visits provided thereafter: Run-in: Participants will commence a three-to-four-week run-in using an updated Medtronic 780g system (BLE2.0 Advanced Hybrid Closed-loop (HCL) system), with user-initiated meal boluses performed 15 minutes prior to eating. The last 14 days of Run-in prior to Stage 1 will serve as baseline glucose control reference. Run-in will last a minimum of three weeks and will not exceed four weeks. The duration of this stage will be dependent on achieving stable device data for the final 2 weeks of the stage, as determined by the investigators. Stage 1: Progression to stage 1 will begin immediately following run-in. All participants will be provided with the NMX-AID system and educated in its use, which will occur in small groups of ~4 people. They will use the device after activating the PumpStart function, enabling immediate AID activation and will announce all meals or snacks by initiating a bolus of insulin approximately 15 minutes before any food. Stage 1 will last a minimum of three weeks and will not exceed four weeks. The duration of this stage will be dependent on achieving stable device data for the final 2 weeks of the stage, as determined by the investigators. Stage 2: Progression to stage 2 will begin immediately following stage 1. All participants will use the NMX-AID system as a full closed loop system where meals will be unannounced (they will be requested not to bolus for any meals) though they will be permitted to correct elevated glucose readings and modify the AID target in preparation for exercise. Stage 2 will last a minimum of three weeks and will not exceed four weeks. The duration of this stage will be dependent on achieving stable device data for the final 2 weeks of the stage, as determined by the investigators. Stage 3: Progression to stage 3 will begin immediately following stage 2. All participants will continue to use the NMX-AID system and will be advised to bolus as they see fit. Stage 3 will last a minimum of three weeks and will not exceed four weeks. The duration of this stage will be dependent on achieving stable device data for the final 2 weeks of the stage, as determined by the investigators. The study will require five study visits, with a minimum of 3 face-to-face visits and 2 visits which may occur remotely. The initial visit will be face-to-face and involve screening and provision of BLE2 devices, and will last approximately 2 hours. After enrollment, participants will be screened with demographic data recorded and a clinical history and physical examination will be performed. Carbohydrate counting knowledge will be reviewed. Guidelines will be provided for correction of hyperglycaemia. Blood will be collected for HbA1c and electrolytes. Participants with Minimed 780G experience who have passed screening will be provided with and educated in the use of the BLE2 system (insulin pumps and sensors) and extended wear insulin infusion sets (EWIS). They will commence Run-in which will last three to four weeks. During Run-in participants will be asked to bolus / administer rapid acting insulin approximately 15 minutes prior to each meal (announced meal-time insulin). The second visit will also be face-to-face, will take approximately 4-6 hours and will involve commencement of Stage 1. All BLE2 insulin pumps and sensors will be collected from participants. Questionnaires will be administered to all participants. All participants will be provided with and trained in the use of NMX-AID pumps and associated sensors. All will be advised to continue to announce meals with an insulin bolus for the 3-4 week duration of Stage 1. The third visit can occur remotely, will last approximately 30mins and will involve commencement of Stage 2. Questionnaires will be administered to all participants. Participants will continue the use of NMX-AID devices but will be advised not to bolus for meals nor for corrections for the 3-4 week duration of Stage 2. The fourth visit can also occur remotely, will take approximately 30mins and will involve commencement of Stage 3. Questionnaires will be administered to all participants. Participants will continue the use of NMX-AID devices but will be able to decide if a pre-meal bolus is required or not for the 3-4 week duration of Stage 3. The fifth and final visit will involve the End-of Study Visit, will take approximately 4-6 hours and will occur face-to-face. Questionnaires will be administered. All study devices will be collected. The participants will return to their usual care after their own device settings have been reviewed. Semi-Structured interviews will be conducted. A blood sample will be collected for measurement of HbA1c.

Sponsors

St Vincent's Hospital Melbourne
Lead SponsorHospital

Study design

Allocation
Non-randomised trial
Primary purpose
Treatment

Eligibility

Sex/Gender
All
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Age > 18 years; T1D of >1 year duration; stable on Medtronic Minimed 780G system pump therapy for >3 months; proficient in carbohydrate counting; HbA1c <10.0%.

Exclusion criteria

Pregnancy or planned pregnancy; eGFR<40; a history of diabetic ketoacidosis in the last 3 months; diabetic gastroparesis; tape allergy major medical or psychiatric illness.

Outcome results

None listed