A multi-centre, prospective, safety and efficacy evaluation study of automated external defibrillation (CellAED) in patients with cardiac arrythmias.

A multi-centre, single arm, prospective, pre-market safety and efficacy evaluation study on automated external defibrillator (CellAED) to terminate arrhythmias in patients (VT or VF) and restore normal sinus rhythm.

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ANZCTR
Registry ID
ACTRN12621000258853
Acronym
RAPID I
Enrollment
23
Registered
2021-03-10
Start date
2021-05-31
Completion date
2025-12-31
Last updated
2025-09-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Brief summary

The CellAED device is a novel automated external defibrillator (AED) or commonly referred to as a defibrillator. The purpose of this study is to test this new AED and demonstrate its ability to deliver an appropriate shock to help restore a patient in cardiac arrest to a normal heart rhythm. The hypothesis is that the CellAED will be able to terminate arrhythmias (VT or VF) in a patient to allow the heart to restore a Normal Sinus Rhythm. Once consented, patients will be scheduled for the cardiac procedure. Patients will have the CellAED applied to their chest prior to the procedure starting. In addition, as a safety precaution, patients will have a traditional defibrillator applied to their chest as a rescue therapy device should the first shock delivered by the CellAED fail to revert the patient to normal sinus rhythm. During the procedure, if patient experiences a shockable rhythm (VT/VF) the cardiologist will activate the CellAED (in accordance with instructions in the Instructions for Use). This will be performed up to a maximum of one (1) time. The rhythm will be immediately assessed and if required, back up defibrillation will be delivered utilizing the standard defibrillator available on site.

Interventions

Once suitable participants have signed the consent form, they will undergo a cardiac procedure. These participants are patients who are already having a planned procedure where they are likely to experience Ventricular Tachycardia (VT) or Ventricular Fibrillation (VF). The CellAED device is a novel automated external defibrillator. The cardiologist will place the CellAED onto the patient's chest once in theatre, prior to the commencement of surgery. During the procedure, participants will be co

Once suitable participants have signed the consent form, they will undergo a cardiac procedure. These participants are patients who are already having a planned procedure where they are likely to experience Ventricular Tachycardia (VT) or Ventricular Fibrillation (VF). The CellAED device is a novel automated external defibrillator. The cardiologist will place the CellAED onto the patient's chest once in theatre, prior to the commencement of surgery. During the procedure, participants will be connected to the CellAED, along with a back-up defibrillator. Once patients experience an arrhythmia (either spontaneous or induced), the CellAED will be deployed to deliver a defibrillation therapy and revert the patient to normal sinus rhythm. This will only be applied to a maximum of 1 time. A back up standard defibrillator will be used if the Cell AED device fails to successfully restore normal rhythm following a single shock delivery from the CellAED. The CellAED will then be removed from the patient. The use of the CellAED will be confined to the duration of the surgical procedure only. The use of the device including placement, therapy delivered, and outcome, will be reported in the patients medical records. Prior to surgery, all involved staff members will be trained on the appropriate use of the CellAED device in a single 30 minute training session. This training will be provided by the study sponsor onsite at the hospital in a one-to-one training session and will utilize a CellAED trainer device. All training will be documented and only trained users will be able to use the device. All users will have access to the trainer device and the instructions for use (IFU) document. This IFU document has been created specifically for this trial.

Sponsors

RRR Manufacturing Pty Ltd
Lead SponsorCommercial sector/Industry

Study design

Allocation
Non-randomised trial
Primary purpose
Treatment

Eligibility

Sex/Gender
All
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

INCLUSION CRITERIA: 1. Patients scheduled for a routine cardiac procedure where they are likely to experience episodes of VT/VF 2. Patient is willing and able to provide written Informed Consent by signing and dating the relevant Ethics Committee approved Informed Consent 3. Patient is 18 years of age or older

Exclusion criteria

EXCLUSION CRITERIA: 1. Patient is considered a member of a protected population (Pregnant, prisoner, mentally incompetent, etc.) 2. Patient is enrolled in a competing/conflicting clinical trial 3. Patient has a condition which would, in the judgement of the investigator, place the patient at undue risk or interfere with the conduct of the study 4. Patient is institutionalised or is a known drug abuser, a known alcoholic or cannot understand the requirements of study participation