Brief summary
TSA is now well established as a means to relieve pain and improve function for a variety of shoulder arthritic conditions. Reverse TSA use has increased, with most joint registries showing that at least 50% of arthroplasty procedures performed involve use of the reverse TSA. Concerns remain however regarding complication and failure rates with reverse TSA, with little medium and no long term outcomes reported in the literature. Many different reverse TSA designs are now in use, including 155 degree neck shaft angle Grammont designs, to designs that utilise either 145 degree or even 135 degree neck shaft angles. Short stem designs are now available, in addition to designs that lateralise the centre of rotation or lateralise the humeral shaft. At present we do not know what the optimal reverse configuration is, and only medium and long term follow-up studies that look specifically at implant design can help answer this question. Longer term outcomes following reverse TSA remains poorly defined, and very little literature is available on newer implant designs. The primary purpose of this study is to critically look at both clinical (patient) and radiographic (Xray) outcomes of the DePuy Delta Xtend reverse TSA. This will to add to the body of literature regarding reverse TSA and specifically to our understanding of this implant and the indications for its use.
Interventions
Clinical (objective and patient derived) outcome analysis at a minimum of 5 years post-op following implantation of Delta Xtend reverse TSA - one clinical assessment and completion of patient questionnaires. Approximate duration of assessment 1.5 hours. Standardised radiographic analysis of Delta Xtend reverse TSA at a minimum of 5 years follow-up to assess for the presence of recognised complications associated with the use of reverse TSA. No maximium duration since surgery. All patients will fall between 5 and 8 years post-op. Analysis of patient outcome and relationship to radiographic findings. Analysis of patient outcome and radiographic findings to pre-op diagnosis. Survivorship analysis looking at re-operation and revision rates.
Sponsors
Eligibility
Inclusion criteria
Retrospective analysis of a consecutive series of prospectively enrolled patients following reverse TSA for a variety of indications using the DePuy Delta Xtend reverse RSA system.
Exclusion criteria
Patients excuded if surgery not carried out by pre-designated surgeon, if a conventional TSA or other form of arthroplasty rather than a reverse TSA was performed, or if an alternative implant was used for the procedure.