Skip to content

B –natriuritic peptide and troponin for diagnosis of cardiac origin weaning failure from mechanical ventilation: An observational study.

B –natriuritic peptide and troponin I as an alternative to echocardiography for diagnosis of cardiac origin weaning failure from mechanical ventilation : An observational study.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ANZCTR
Registry ID
ACTRN12616000143426
Enrollment
80
Registered
2016-02-05
Start date
2013-04-06
Completion date
2014-04-02
Last updated
2020-01-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Brief summary

to evaluate B–natriuritic peptide and troponin I as an alternative to echocardiography for diagnosis of cardiac origin weaning failure from mechanical ventilation.

Interventions

Patients were categorized into 3 groups according to spontaneous breathing trial outcome: Group I: Heart failure group (heart failure as a cause of weaning failure). Group II: Respiratory failure group (respiratory cause of weaning failure). Group III: Success group. Demographic data, causes of mechanical ventilation and severity score APACHE II (Acute Physiology And Chronic Health Evaluation) score; were recorded at admission to intensive care unit. Clinical, laboratory and echocardiographic

Patients were categorized into 3 groups according to spontaneous breathing trial outcome: Group I: Heart failure group (heart failure as a cause of weaning failure). Group II: Respiratory failure group (respiratory cause of weaning failure). Group III: Success group. Demographic data, causes of mechanical ventilation and severity score APACHE II (Acute Physiology And Chronic Health Evaluation) score; were recorded at admission to intensive care unit. Clinical, laboratory and echocardiographic data have been obtained immediately before and at the end of the spontaneous breathing trial. Sample collection and biomarker assays: All arterial blood gases were measured using a blood gas analyzer. BNP and troponin I were measured in venous whole blood by staff blinded to clinical and echocardiographic findings. Echocardiography Transthoracic echocardiograms were performed in all patients immediately before and at the end of spontaneous breathing trial. Diastolic function was evaluated with pulse-wave doppler imaging and pulmonary flow measuring blood flow through the mitral valve. Systolic function was assessed in the apical four-chamber view. All echocardiography measurements were performed by cardiologist blinded to the natriuretic peptide, troponin I concentrations and SBT results. Heart failure will be diagnosed by the presence of echocardiography indices suggestive of filling pressures

Sponsors

Hoda Alsaid Ahmed Ezz
Lead SponsorIndividual

Eligibility

Sex/Gender
All
Age
60 Years to No maximum
Healthy volunteers
No

Inclusion criteria

The patients were selected from elderly patients aged more than 60 years old, who were under mechanical ventilation for more than 48 hours and fulfilling the criteria of weaning.

Exclusion criteria

Patient below the age of 60 years old, with renal failure, end stage chronic illness, preexisting neuromuscular disease, and patients without good transthoracic echocardiography window.

Outcome results

None listed

Source: ANZCTR · Data processed: Feb 4, 2026