Skip to content

An evaluation of user acceptance and performance of a mobile real-time continuous glucose monitoring system in people with type 1 and type 2 diabetes.

An evaluation of user acceptance and performance of a mobile real-time continuous glucose monitoring system in people with type 1 diabetes (T1D) and with type 2 diabetes treated with multiple daily injections (MDI) of insulin.

Status
Withdrawn
Phases
Unknown
Study type
Interventional
Source
ANZCTR
Registry ID
ACTRN12616000005459
Enrollment
20
Registered
2016-01-12
Start date
2016-02-01
Completion date
Unknown
Last updated
2020-01-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Brief summary

Until recently, insulin administration has been based upon finger-prick measurements of capillary glucose readings. RT-CGM involves using a subcutaneous sensor to measure interstitial fluid glucose levels continuously and provides the patient with the glucose level in real-time, as well as the rate and direction of change in the glucose. While there is an increasing body of evidence indicating that RT-CGM in combination with an insulin pump results in an improvement in glycaemia and reduces hypoglycaemia, compared with self monitoring of blood glucose (SMBG) and MDI in people with T1D, data is limited regarding the use of RT-CGM in conjunction with MDI. The study aims to evaluate the user acceptance of the RT-CGM device in patients with T1D, and T2D on MDI, as well as to evaluate its' impact on glycaemic control.

Interventions

This study aims to evaluate the user acceptance of a real time continuous glucose monitoring (RT-CGM) system in people with T1D and T2D treated with MDI of insulin. This study also intends to evaluate the performance of the system and the the impact it has on glycaemia. The RT-CGM system consists of a glucose sensor and transmitter and a linked study iPod displaying glucose information. The glucose sensor is inserted subcutaneously, in the abdomen region, and measures glucose in the interstiti

This study aims to evaluate the user acceptance of a real time continuous glucose monitoring (RT-CGM) system in people with T1D and T2D treated with MDI of insulin. This study also intends to evaluate the performance of the system and the the impact it has on glycaemia. The RT-CGM system consists of a glucose sensor and transmitter and a linked study iPod displaying glucose information. The glucose sensor is inserted subcutaneously, in the abdomen region, and measures glucose in the interstitial fluid (IF) through a glucose oxidase reaction. This study is a randomized crossover study involving 20 participants (10 with T1D and 10 with T2D using MDI of insulin). Participants will undertake one week of unmasked RT-CGM system (where there will be able to see their CGM information) linked to a study iPod , and one week of masked RT-CGM system (where they will not be able to see their CGM information) linked to a glucose senor recorder (GSR), in random order. Following baseline clinical assessment, researchers will provide participants with education about study devices. Initial venous blood sampling for HbA1c and 1,5 AG will be taken. 1 hour following sensor insertion, participants will undergo frequent venous blood samples (FST) to measure plasma glucose at 20 minute intervals for a duration of 3 hours. . For the 2 week study period participants will be instructed to undertake reference capillary blood glucose measurements (a minimum of 4 times a day) and to wear the RT-CGM system continuously. For the study duration participants will be instructed to keep a diary documenting activity, diet, capillary glucose reading, insulin, and symptomatic hypoglycaemia episodes. Participants will attend a study visit on Day 8. Participants assigned to the unmasked RT-CGM arm will complete a user evaluation questionnaire. A standard meal will be provided to both groups and venous bloods for glucose will be collected from the start of the meal at 20 minute intervals for a duration of 5 hours. Two hours post-meal a second sensor will be inserted to allow for crossover of the study, where the sensor will be linked to the alternative GSR or iPod. The sensor inserted on Day 1 will be removed and collected for review of the data prior to the participants departure. On Day 15 participants will attend their final study visit. Participants assigned to the unmasked RT-CGM for the second half of the study will complete a user evaluation questionnaire. An intravenous cannula will be inserted to the cubital fossa and venous blood for HbA1c and 1,5 anhydroglucitol (1,5 AG) will be taken. Participants will then be provided a meal and have venous blood collected at this time at 20 minute intervals over the following 3 hours for plasma glucose measurements.

Sponsors

St Vincents hospital Melbourne
Lead SponsorHospital

Study design

Allocation
Randomised controlled trial
Intervention model
Crossover
Primary purpose
Prevention
Masking
Open (masking not used)

Eligibility

Sex/Gender
All
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

-T1D, or T2D of >10 years duration treated with MDI of insulin -Participant willing to comply with study protocol

Exclusion criteria

-Pregnant or planned pregnancy during the study period -Life-threatening illness -Major psychiatric illness

Outcome results

None listed

Source: ANZCTR · Data processed: Feb 4, 2026