Skip to content

Is a new type of socket joint of a hip prosthesis stable without the use of screws in patients undergoing total hip replacement?

Radiostereometric analysis of acetabular component migration following randomisation to either a non-holed tantalum trabecular metal-coated acetabular shell or a cluster-holed titanium fibre metal-coated acetabular shell fixed with one or two screws in patients with osteoarthritis scheduled to undergo primary total hip replacement through posterior a approach

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ANZCTR
Registry ID
ACTRN12613000882729
Enrollment
64
Registered
2013-08-07
Start date
2007-03-15
Completion date
2013-10-15
Last updated
2020-01-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Brief summary

This randomised controlled trial aims to determine whether a tantalum trabecular metal acetabular component in a primary total hip replacement prosthesis can achieve adequate initial fixation without the use of screws. This study utilises radiostereometric analysis, the most sensitive radiographic technique available to measure acetabular component migration in vivo.

Interventions

Primary total hip replacement using a tantalum trabecular metal coated acetabular shell. This is a surgical procedure where the femoral head is removed and replaced by a 28 mm metal prosthetic femoral head, which is attached to a femoral stem inserted into the femur. The head then articulates with a plastic (highly cross-linked polyethylene) liner in a metal acetabular shell, which is inserted into the acetabulum. Initial stability of the shell is achieved by press-fit fixation, without the use

Primary total hip replacement using a tantalum trabecular metal coated acetabular shell. This is a surgical procedure where the femoral head is removed and replaced by a 28 mm metal prosthetic femoral head, which is attached to a femoral stem inserted into the femur. The head then articulates with a plastic (highly cross-linked polyethylene) liner in a metal acetabular shell, which is inserted into the acetabulum. Initial stability of the shell is achieved by press-fit fixation, without the use of screws. The duration of the operation is between about 45 minutes and 4 hours, depending on the complexity of the operation. During the operation tiny tantalum beads are inserted into the periprosthetic bone to enable determination of acetabular component migration using a highly sophisticated radiographic technique, namely radiostereometric analysis.

Sponsors

Prof Donald Howie
Lead SponsorIndividual

Study design

Allocation
Randomised controlled trial
Intervention model
Parallel
Primary purpose
Treatment
Masking
Open (masking not used)

Eligibility

Sex/Gender
All
Age
40 Years to 64 Years
Healthy volunteers
No

Inclusion criteria

1. undergoing primary total hip replacement through posterior approach 2. diagnosis of osteoarthritis 3. walking ability restricted only by hip pathology

Exclusion criteria

1. previous infection 2. inflammatory arthritis 3. Crowe-2 DDH or worse dysplasia 4. abnormal acetabulum 5. increased risk of osteopaenia

Outcome results

None listed

Source: ANZCTR · Data processed: Feb 4, 2026