Continuous Positive Airway Pressure(CPAP) Therapy Comfort

An evaluation of the comfort of modified CPAP devices in patients with obstructive sleep apnoea

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ANZCTR
Registry ID
ACTRN12613000712707
Enrollment
161
Registered
2013-06-28
Start date
2013-07-15
Completion date
2015-09-21
Last updated
2020-02-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Brief summary

CPAP Therapy is the gold standard treatment for OSA, which has been proven to be extremely effective over the last 30 years. Adherence to therapy remains sub-optimal, and as such technological improvements to improve patient comfort and adherence, are continually being developed. The technological improvements need to be evaluated for comfort by the treatment population, in order to inform product development. These evaluations are to gauge acceptance and preference of one solution over another, before investing further development for a final product and assessing treatment efficacy.

Interventions

CPAP devices with modifications designed to increase patient comfort - to be trialled by subjects for comfort and preference only. 1. Two different devices will be trialled, each offering a different pressure control method (how stable the pressure is when breathing in and out). Device 1 will keep the pressure in the mask as low as possible. Device 2 will provide some pressure relief on expiration (in the region of 1-2cmH2O). 2.a) Subjects will breathe on the device while awake for short periods

CPAP devices with modifications designed to increase patient comfort - to be trialled by subjects for comfort and preference only. 1. Two different devices will be trialled, each offering a different pressure control method (how stable the pressure is when breathing in and out). Device 1 will keep the pressure in the mask as low as possible. Device 2 will provide some pressure relief on expiration (in the region of 1-2cmH2O). 2.a) Subjects will breathe on the device while awake for short periods of time (minimum of 2 minutes and < 30 minutes) b) Patients will be tested on a sub-therapeutic pressure (as they are awake and don't require treatment). This pressure is determined by the minimum pressure the device can produce whilst safely flushing CO2. c) All participants will try all devices. The wash-out period between devices will be at least half as long as the time spent breathing on the device (between one minute and 15 minutes). Different mask prototytpes will be trialled with CPAP while the patient is awake.

Sponsors

Fisher & Paykel Healthcare
Lead SponsorCommercial sector/Industry

Study design

Allocation
Randomised controlled trial
Intervention model
Crossover
Primary purpose
Treatment
Masking
Blinded (masking used) (Subject)

Eligibility

Sex/Gender
All
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

Aged 18 years or older Able to give informed consent (this study will include healthy volunteers, patients that are awaiting a sleep study with a suspicion of OSA, and patients diagnosed with OSA)

Exclusion criteria

Contraindicated for CPAP/AutoCPAP therapy Must not require supplemental oxygen Must not have critical medical device (i.e. cardiac pacemaker)

Outcome results

None listed