Feasibility study of a novel glucose sensor in type 1 diabetes

A feasibility study examining a novel orthogonally redundant continuous glucose sensor in type 1 diabetes

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ANZCTR
Registry ID
ACTRN12613000705785
Acronym
ORS
Enrollment
18
Registered
2013-06-28
Start date
2013-07-01
Completion date
2014-01-13
Last updated
2020-01-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

None listed

Brief summary

Glucose sensor technology for continuous glucose monitoring (CGM) in diabetes has been evolving with an ultimate goal of achieving a level of reliability and accuracy required to replace finger prick glucose measurement. Although CGM technology advances have increased accuracy, reliability and ease of use, further improvements are required. A CGM system based on a novel technology platform has been developed. Early laboratory testing, animal studies and limited testing in humans indicates that further human studies are warranted. This feasibility study of the novel glucose sensor is the first extensive testing of this sensor in humans.

Interventions

A feasibility study to assess the accuracy and reliability of a novel continuous glucose monitoring (CGM) system in vivo in people with type 1 diabetes. For the duration of the study participants will concurrently wear two glucose sensors: 1) the investigational device - an electrochemical and optical fluorescence-based orthogonally redundant sensor (ORS), and 2) a non-redundant electrochemical sensor based on current CGM platforms. Each sensor will be inserted subcutaneously into the abdomen u

A feasibility study to assess the accuracy and reliability of a novel continuous glucose monitoring (CGM) system in vivo in people with type 1 diabetes. For the duration of the study participants will concurrently wear two glucose sensors: 1) the investigational device - an electrochemical and optical fluorescence-based orthogonally redundant sensor (ORS), and 2) a non-redundant electrochemical sensor based on current CGM platforms. Each sensor will be inserted subcutaneously into the abdomen using a dedicated sensor inserter, a procedure which takes under 5 minutes. Immediately after sensor insertion, venous samples will be collected at 30 minute intervals for 4 hours for plasma glucose and glucose meter levels. After 48 or 72 hours +/- 4 hours of sensor wear participants will return to the clinical trials centre (CTC) and consume a standardised meal. Venous samples will be collected at 15 minutes intervals from 1 hour prior to the test meal until 3 hours post-meal for plasma glucose and glucose meter levels. Between visits to the CTC, finger prick glucose measurements will be performed a minimum of 6-8 times per day (spread throughout the day pre-meals and two hours post-meals) for the duration of the study. Glucose data from the study devices will not be available to the participants and will not impact on decisions involving their care. All participants will wear both sensors (investigational ORS and electrochemical) for up to 168 hours, with the first participant wearing the devices for 48 hours +/- 4 hours, followed by stepped increases in duration of wear up to 168 hours +/- 4 hours based on data analysis of prior data from participants.

Sponsors

St Vincent's Hospital Melbourne
Lead SponsorHospital

Study design

Allocation
Non-randomised trial
Intervention model
Single group
Primary purpose
Treatment

Eligibility

Sex/Gender
All
Age
21 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

Clinical diagnosis of type 1 diabetes, insulin treatment for diabetes, experience with glucose sensor use.

Exclusion criteria

Pregnant or planned pregnancy within study period, inability to tolerate tape adhesive in the area of device placement, adverse skin condition in the area of device placement.